Article 5: Development Standards
Section 5.7. Perimeter and Streetyard Buffers
5.7.4. Buffer Type Standards
June 23, 2017
Morrisville, NC
Page 5-34
Unified Development Ordinance
Table
5.7.4: Buffer Type StandardsM
INIMUM
W
IDTH AND
S
CREENING
R
EQUIREMENTS
Also see general requirements for all buffer types at bottom of table.
Buffer Type D (Perimeter)
This perimeter buffer provides a relatively open tree buffer between developments on adjoining properties. It is not intended to screen views but
to enhance visual appeal of the development.
Option 1
Shade trees: 3 per 100 linear feet, with at least
20 feet between mature canopies
Understory trees: 3 per 100 linear feet
Option 2
Shade trees: 2 per 100 linear feet, with at least
20 feet between mature canopies
Understory trees: 3 per 100 linear feet
A solid fence or wall at least 3 feet high or
solid evergreen hedge at least 3 feet and 2
feet wide [1]
Buffer Type E (Perimeter)
This perimeter buffer provides a continuous opaque screen to a height of at least six feet. It serves as a visual and noise barrier between a
development and an adjoining major utility facility.
Option 1
Shade trees: 6 per 100 linear feet, with at least
5 feet between mature canopies
Understory trees: 4 per 100 linear feet
Evergreen shrubs: 20 per 100 linear feet and
at least 6 feet high at maturity
At least 50% of all trees must be evergreen
Option 2
Shade trees: 5 per 100 linear feet, with at least
5 feet between mature canopies
Understory trees: 3 per 100 linear feet
Evergreen shrubs: 15 per 100 linear feet and
at least 3 feet high at maturity
A solid fence or wall at least 6 feet high [1]
At least 50% of all trees must be evergreen