Not sure which size radiators you need?

Recommended performance table

(Watts per square metre)

For rooms with ceilings heights up to 3 metres

For rooms with ceiling heights from 3 metres to 3.5 metres

For rooms with ceiling height of 4 metres and above

contact Haverland UK for calculation details.

Measure the room. You will need to know the length and width

of the room as well as the height of the ceiling in metres.

Example: 5 metres x 3 metres = 15 square metres

Total sq m = 15 sq m x 100 watts = 1500 watts

Recommendation: 1 x RC12 TT = 1500 watts

Example: 6 metres x 5 metres = 30 square metres

Ceiling height: 3.5 metres ÷ 3 = 1.16

Multiply 30 sq m x 1.16 = 34.80 cubic metres

Total cubic metres = 3.4.80 sq m x 100 watts = 3,480 watts

Recommendation: 2 x RC12 Compact TTi @ 1800 watts each = 3600 watts

These calculations should be considered as average depending on location, orientation and insulation.

MAKING HEATING CALCULATIONS

Up to 3m height

3m to 3.5m height

Model

Watts

Max sq.m room

RC 4 TT

500

5

RC 6 TT

750

7.5

RC 8 TT

1000 10

RC 10 TT

1250 12.5

RC 12 TT

1500 15

RC 8 Compact TTi

1000 10

RC 10 Compact TTi

1500 15

RC 12 Compact TTi

1800 18

Model

Watts

Max sq.m room

RC 4 TT

500

4.31

RC 6 TT

750

6.47

RC 8 TT

1000 8.62

RC 10 TT

1250 10.78

RC 12 TT

1500 12.93

RC 8 Compact TTi

1000 8.62

RC 10 Compact TTi

1500 12.93

RC 12 Compact TTi

1800 17.24

Zone A

Zone B

Zone C

Zone D

Facade

orientation

CLIMATE ZONE

Not insulated

North South

100 95 90 80

105 100 95 85

110 105 100 90

115 110 105 95

Normal insulation

North South