Technical Information

Warnings and Cautions

Terms and Conditions

SPEED REDUCER NOMENCLATURE & DEFINITIONS

BACKLASH

– Rotational movement of the output shaft when holding the input

shaft stationary and rotating the output alternately clockwise and counter clockwise.

Backlash is defined as the clearance between adjacent tooth flanks in a pair of

mounted gears. In any gearset, some amount of backlash (clearance) is necessary

to prevent damage brought about by gear tooth interference. Lack of backlash may

cause noise, overloading, overheating of gears and bearings and even seizing and

failure.

CENTER DISTANCE

– On a single reduction reducer, this is the distance between the

center lines of the input and output shafts. Shaft center lines may be parallel or at right

angles to one another. The center distance of multiple stage reducers usually refers to

the lowest speed stage (last reduction).

THRUST LOAD

– Forces imposed on a shaft parallel to the shaft axis. It is often

encountered on shafts driving mixers, fans, blowers and similar machines. When

thrust load acts on a speed reducer, you must be sure that the thrust load rating of the

UHGXFHU LV KLJK HQRXJK WKDW LW·V VKDIWV DQG EHDULQJV FDQ DEVRUE WKH ORDG

MECHANICAL RATING

– The maximum power or torque that a speed reducer can

WUDQVPLW EDVHG RQ WKH VWUHQJWK DQG GXUDELOLW\ RI LWV FRPSRQHQWV LV LW·V PHFKDQLFDO

rating. Obviously, the reducer may be rated no higher than the strength or durability

of its weakest component. Reducers typically have a safety margin of two to three

on their mechanical ratings. Thus, a reducer can withstand momentary overloads of

200-300% of its mechanical rating during a start up or other brief overload situations.

MOUNTING POSITION

– The relationship of the input and output shafts relative to

the floor line.

HORSEPOWER

– A measure of the rate of doing work and equals the power required

to lift 33,000 pounds one foot in one minute.

INPUT HORSEPOWER

– The amount of power applied to the input shaft of a

UHGXFHU E\ WKH SULPH PRYHU LV LW·V LQSXW KRUVHSRZHU ,W LV RIWHQ XVHG DV D VHOHFWLRQ

basis for power transmission components, and it appears in the rating table of drive

PDQXIDFWXUHU·V SXEOLVKHG GDWD 5HPHPEHU WKDW LQSXW KRUVHSRZHU UDWLQJV UHSUHVHQW

the maximum amount of power that the reducer can safely handle.

OUTPUT HORSEPOWER

– The amount of power available at the output shaft of

D UHGXFHU LV LW·V RXWSXW KRUVHSRZHU 'XH WR ORVVHV FDXVHG E\ LQHIILFLHQF\ RXWSXW

horsepower is always less than input horsepower.

TORQUE

– A twisting effort tending to cause rotation. Because most power

transmission is associated with rotating elements, torque becomes important as a

measurement of the effort required to produce work in the rotational mode. Torque

is expressed as a force multiplied by a lever arm. It is stated in several units – pound

feet, pound inches, ounce inches, ounce feet, etc. However, the most commonly used

is pound inches.

In the case of speed reducers and gears, force or load is usually expressed in pounds

and distance in inches. For example, if a load of 10 pounds is applied to a shaft by

means of a wrench 9 inches long, we then have a torque of 10 pounds x 9 inches or

90 lb. in.

It is important to note that torque measurement is not dependent on time. The same

amount of torque may be required to run a shaft slowly or rapidly, but the introduction

of a time element causes work to be performed, and work is measured in terms of

horsepower. Consider the application of drawing water from a well via winch and

bucket.

In raising a 50-pound pail of water with a 10-inch diameter (5-inch radius) drum and a

10-inch crank arm, 25 pounds (neglecting friction) must be applied to the 10-inch crank

arm to overcome the torque created by the weight of the pail of water acting on the

5-inch drum radius. If no motion is involved, the system is in balance, and although

torque is being exerted, no work is being done. If the crank is turned at the rate of 10

RPM, the resulting work done is:

HP = T x RPM

=

250 x 10 =

approx .04 HP

63,000

63,000

If the crank is turned twice as fast, the horsepower expended becomes:

250 x 20 =

approx .08 HP

63,000

Therefore, exerting the same torque at twice the speed requires twice the horsepower.

RATIO

– is defined as the driving speed divided by the driven speed. If a 1750 RPM

electric motor is used to drive a 350 RPM conveyor, the ratio would be a q750/350 =

5:1. Ratio is useful for calculating speed reduction and torque multiplication from driver

to driven member. For example, a 5:1 ratio Uniline speed reducer directly connected

to an electric motor would reduce the motor speed to 1/5 of its original value while

multiplying the motor torque to 5 times the original value (neglecting friction loses).

SPEED REDUCER SELECTION

– Before a reducer can be selected for any given

application, the equivalent horsepower is computed by multiplying the specified or

actual horsepower by the service factor for the particular load classification for which

the unit is to be used. It is necessary that the unit selected have a capacity equal to

or in excess of this equivalent horsepower. The recommended service factors for

various load classifications and duration of service are shown for several types of

prime movers on page 644.

Load classifications for various applications are given on page 644. They are

classified into three commonly recognized load classifications: Uniform, Moderate

Shock, and Heavy Shock.

Service factors represent the normal relationship between gear design power rating

and the continuous power requirements. Applications involving unusual or severe

loading or requiring a high degree of dependability should be carefully reviewed with

the manufacturer before a service factor is applied.

Applications with high-torque motors and motors for intermittent operations,

applications where extreme repetitive shock occurs, or where high-energy loads must

be absorbed, as when stalling, require special consideration and are not covered by

the service factors given on page 644.

When drives are equipped with brakes on the input, and the torque rating of the brake

exceeds the rating of the motor, the rating of the brake dictates the selection of the

gear unit.

The maximum momentary or starting load must not exceed 300 percent of rated load

(200 percent overload). Rated load is defined as the unit rating with a service factor

of 1.0.

Technical Information