6-1-14

CHANNEL DRAINS

1. Determine location for channel drain

2. Install subfloor andbacker board adhering to local codes

3. Cut hole in floor allowing additional ¼". Allow access to fit and clampno hub coupling. See Fig1

4. Install no hub couplingonto channel drain

5. Apply abeadof silicone caulking to the undersideof tile flange

6. Install channel drain, by attaching no hub coupling to existingpiping

7. Cut your pattern intomembrane

8. Install waterproofmembrane as permanufacturer’s instructions. Adheremembrane to tile flange

on channel drain usingmembranemanufacturers recommended adhesive

9. Apply thin setmortar and install tile

10.Once above is completed anddry, install channel draingrate

11.Install grate in channel drainbase. If required, adjust legs ongrate level with tileprofile. Legs

extend clockwise rotationor retract counter clockwise rotation. Adjust all legs tobase todistribute

grate level evenly onbase. (N/A for JACLO SLIM)

INSTALLATION INSTRUCTIONS

zeroEDGE/SLIM -

No subdrain required

Figure 1

listed no hub

couplingby others

Retract

Extend

Grate legs

tile

flange

adhesive

grate

finished

tile edge

channel drain

subfloor

tilebase

tile

thinset/mortar