Automation, process control and instrumentation
⎪
byE+Htobe the fastest reacting sensors in themarket.
The sensors come with a welded hygienic process
connection. In the standardpackage (Figure2) theyare
installed in three tanks –water, caustic and acid– after
the heat exchanger and in the backflow. The tempera-
ture control within the process gains speed because
the tanks can be heated up internally before the CIP
process is started. It is the same for the concentration
of caustic and acid. Including a CLS54D conductivity
sensor in each of the tanks will determine the concen-
tration, evenwhen theCIPplant is not in operation, so
the media are always properly prepared.
The conductivity sensor is equipped with an
internal temperature sensor to compensate for the
influence of changing temperatures. Connected to a
central CM44x transmitter, the signals of both can be
converted into a concentration value. The transmitter
(also available for DIN rail installation) can host up to
eight sensors. This allows the phase shift meter in the
backflow to be either a compact CLD18 or a CLS54D.
Instead of a flow switch, the electromagnetic
Promag 10H flow meter is used. This hygienic sensor
supplies the information more accurately than the
flowphant by using the flowrate signal. The Liquipoint
limit switches are replaced by liquiphant vibration
point level switches. They are installed in the three
tanks and positioned in front of the supply pump and
the return pump. Liquiphant level switches are easier
to commission and work with all liquid media, even if
not conductive and are the standard sensors in this
application. The RSG35 still has the capacity to show
and report all relevant data.
There are sensor options to choose from that im-
prove theCIPcontrol system. They supply information
more accurately and faster, helping to save water, en-
ergy, cleaning agents and time. The higher investment
costs often be recouped in a very short time thanks to
reducedoperational costs. Hygienic design adds some
cost to a project, but the savings in every phase shift,
during production or cleaning support short return on
investment periods.
In the advanced system (Figure 3), velocity is
measured with a Promag H 100. Based on the same
hygienic sensor, this unit is equipped with a more
sophisticated transmitter than thePromag 10H. After
each cleaning, the Heartbeat™ Verification tool veri-
fies the sensor is working within its specification. The
Promag H 100 features empty pipe detection that
Figure 1:
The CIP
starter package for
Endress+Hauser enables
simple automation of CIP
processes.
Figure 2:
CIP standard
package includes options
that supply information
more accurately and faster,
helping to save water, en-
ergy, cleaning agents and
time.
Figure 3:
In the advanced
automation package,
velocity is measured with
a Promag H 100, which
is equipped with a more
sophisticated transmitter.
recognises when the return pipe is completely filled,
even when installed horizontally. Flow can still be
measured when the pipe is not full, however, an alarm
signal is then given to suggest the system may not be
cleaned completely.
TwoSmartecCLD134compactdevicesareinstalled
in the two agent tanks when a local display is needed.
Two CLS54D sensors connected to the CM44P
transmitter can be used to measure conductivity and
directly calculate concentration. The same contact
device is used in the return line. It detects variation
in the concentration of the returning cleaning liquid
as fast as possible.
TheTM401QuickSensisusedtomeasuretempera-
ture and control themake-up in the tanks. The TM411
QuickNeck is installed in the backflow, after the heat
exchanger. These temperature measurements are
important tomaintain consistent quality, and frequent
sensor calibrationprovides the required level of safety.
The QuickNeck is installed with a specific fixed bayo-
net thermo-well so the entire loop can be calibrated
without opening the process or cable connection. The
spring-loaded Pt 100 element is still in close contact
with theprocess and thereforehas a fast T90 response
time. The limit switches are replaced with a hygienic
sensor that uses a combination of capacitance and
conductivity technologies.
Supplying the same easy, flexible operation as the
Liquiphant, the Liquipoint FTW33 can be installed
flush-mounted. This is the next step inhygienic design.
The Liquipoint’s function can be easily tested with
a service magnet, without opening the process. The
central unit is changed to a RSG35 data recording
and displaying system in order to properly display this
complex system and record more values.
The differentiator in this high end system is the
OUSAF11absorptionsensor.Thissensor,connectedto
the same CM44P as the conductivity sensors, quickly
detects when the majority of the product remains are
flushed out of the system, enabling demand-driven
(instead of time-controlled) flushing. This saveswater
andprotects the caustic frombeing loadedmore often
thannecessary. Nevertheless, thefirst caustic pumped
through the system takes the majority of impurities
with it. It makes sense to drain this caustic rather than
to recycle it into thebuffer tank, where it contaminates
theothercaustic.Thisresultsinabetteruseofcaustics,
which leads to lower costs.
q
Figure 2
Figure 3