KHS GmbH

Juchostraße 20

D-44143 Dortmund

Deutschland

Tel: +49.231.569 0

info@khs.com

* Subject to technical modifications and price changes. On request, we will be glad to provide you with a binding offer.

Version 2 Date 17.07.2014

Description

Innofill CO2 savings for filler types DRV VF and VF/N from YOM 2006. By

adding an extra gas cylinder the nozzles to the return gas channel are only

opened for slow filling and snifting instead of the nozzles to the return gas

channel being permanently open, as in the single-chamber system.

Benefit

As the CO2 nozzles to the return gas channel open and close automatically - as

opposed to the single-chamber filling system - up to 70% of the CO2

previously consumed can be saved.

Economic efficiency calculation

ROI assumptions Filling volume in hectoliters per hour: 625 Price for 1,000 kg

of CO2: €1

60 Savings as opposed to the single-chamber system:

75% CO2 per hour in kg (118 kg instead of 375 kg)

€42 per hour • €336 per eight-hour shift per day

€672 with two shifts per day

€3,360 per week (five days) with two shifts per day

€168,000 per 50 weeks with two shifts per day

Scope of supply

Gas cylinder

Additional valve cartridges

New filling program

Center valve parts