o
Modern RT planning in lymphoma incorporates the current concepts of
volume determination as outlined by ICRU Report 83
o
It is based on defining a gross tumor volume (GTV) and a clinical target
volume (CTV), that is expanded to a planning target volume (PTV)
o
The PTV is then used to define beam coverage
o
This approach allows direct comparison with the diagnostic 3D-imaging,
increasing the accuracy with which lymph node volumes are defined
Treatment Volume Principles