3
data. Expressed as the reproducibility relative standard deviation (SD
R
); or % reproducibility
97
relative
standard deviation (% RSD
R
).
98
99
100
4.
Method Performance Requirements:
101
3-MCPD
102
103
3-MCPD *
in dry samples
(powder)
3-MCPD
*
Liquid in liquid samples
Analytical range
25 – 500
*µg/kg
3 – 60
* µg/kg
LOD
N/A
N/A
LOQ
≤ 25
* µg/kg
≤ 3
* µg/kg
Accuracy (from spiked recovery)
75-110%
75-110%
% RSD
r
≤ 14%
≤ 14%
%RSD
R
≤ 20%
Selectivity Study
* overall analyted content resulting either from separate or from combined
determination of free 3-MCPD and bound 3-MCPD.
104
105
2-MCPD
106
107
2-MCPD **
in dry samples
(powder)
2-MCPD**
Liquid in liquid samples
Analytical range
LOD
LOQ
Accuracy (from spiked recovery)
% RSD
r
%RSD
R
Selectivity Study
** overall analyted content resulting either from separate or from combined
determination of free 2-MCPD and bound 2-MCPD