SIOP UMBRELLA – RT

Target Volume Definition

GTV: based on the combination of pre-operative

imaging, (clips?) and the reports by the surgeon

and pathologist. Includes the contact zone of the

pre-surgery tumour

CTV: Expanded GTV with an anatomically

confined margin of 5-10 mm (without expansion

into the intestines) including the para-aortic

lymph node chain in case of lymph node

involvement