55

www.read-wca.com

Wire & Cable ASIA – November/December 2015

Leoni Studer AG

Business Unit Solar & Windpower

Däniken

Switzerland

Tel

: +41 799138728

Email

:

faruk.yeginsoy@leoni.com

Website

:

www.leoni.com

6.2 IEC

In 2013 IEC adopted the draft EN50618 on request of IEC

TC82 as a basic paper to start to work out an IEC standard

for photovoltaic wires.

This is now published as a committee draft IEC62930.

The IEC draft is 95 per cent identical to EN50618.

6.2.1 The difference to EN50618

The main difference between EN 50618 and IEC 62930

is that in the IEC standard class two conductors are

permitted for use for fixed installations.

7 What is new in EN50618 and IEC

62930

7.1 Design

There are no great differences in the design requirements

of these new standards. Notice, however, the definition of

black as preferred jacket colour.

Minor changes are in the required layer thicknesses, which

are slightly increased.

7.2 Test requirements

Note that the material testing procedures have been widely

changed by adapting IEC60811 ”Electric and optical fibre

cables – Test methods for non-metallic materials”.

• All test samples now have to be taken from finished

cables

• It is not permitted to conduct material tests on

extruded tapes or moulded plates

Paper courtesy of the 63

rd

IWCS Technical Symposium,

Providence, Rhode Island, USA, November 2014.