Recommendation for reporting

Rationale for

SRT near-maximum

and

near-minimum dose

:

Ø

ICRU 83

introduced

D

2%

and

D

98%

Ø

An absorbed dose is reported that is NOT DEPENDING on a single

computation point and suffers less from sampling errors and

calculation uncertainties.

Ø

ICRU 91

, for small PTV, SRT near-maximum dose is

D

V

, where V

represents a minimal absolute volume element within which the

absorbed dose can be calculated to sufficient accuracy

.

Ø

This volume element needs to be chosen taking into account the

calculation grid size and considerations related to dose-calculation

accuracies in a single voxel.

Ø

Turns out that absolute volumes of

30-35 mm

3

seem adequate

(Benedict 2010, Roberge 2015).

SBRT 2017 - D. Verellen