_______________________________________________________________________________________________

constraints seem suboptimal for sparing rectum when

using IMRT. However, tighter dose constraints may result

in higher dose inhomogeneities in the PTV. The treatment

modalities that had lower NTCP values were inferior in

many cases regarding the risk for secondary malignancies.

Consequently, the optimization of different treatment

modalities and plans should be complemented by the

estimation of the corresponding risks for developing

secondary malignancies.

EP-1560 Left breast cancer planning with VMAT

technique: the dosimetric trade-offs

A. Fogliata

1

, J. Seppala

2

, G. Reggiori

1

, F. Lobefalo

1

, V.

Palumbo

1

, F. De Rose

1

, D. Franceschini

1

, M. Scorsetti

3

, L.

Cozzi

3

1

Humanitas Research Hospital, Radiation Oncology,

Milan-Rozzano, Italy

2

Kuopio University Hospital, Cancer Center, Kuopio,

Finland

3

Humanitas Cancer Center and Humanitas University,

Radiation Oncology, Milan-Rozzano, Italy

Purpose or Objective

: Intensity modulation with volumetric modulated arc

therapy (VMAT) for breast cancer treatment has been

explored, proving that, as a trade-off of improved target

dose distributions, larger volumes of the surrounding

tissues receive a more or less pronounced low dose bath.

Clinical results demonstrating a detrimental effect of the

low-dose bath, related to volume and dose levels, with

respect to the two-tangential beam dose delivery, or the

associated risk of secondary cancer induction, are

currently not available. In the absence of such data, a

good approach is to drive the inverse VMAT optimization

processes to decrease the dose to all the critical

structures as much as possible, and to maximize the target

dose homogeneity. This can be primarily achieved by

means of adequate beam arrangement, and by highly

restrictive planning objectives, more restrictive than the

clinical need. Scope of this work is to evaluate the possible

trade-offs in breast VMAT planning, exploring the degree

of achievable dosimetric sparing of different organs at risk

(OAR) by using two quite similar VMAT plan settings.

Material and Methods

CT scans of 20 patients presenting left sided breast

cancer, in deep inspiration breath hold, were studied.

VMAT plans were optimized for the RapidArc technique in

the Eclipse treatment planning system (Varian) using the

PO algorithm and were calculated with Acuros, to deliver

40.05Gy to mean target dose in 15 fractions. Two partial

arcs were arranged for 6MV, Millennium MLC from a

TrueBeam linac (Varian). Two plans per patient were

optimized: RA_full, where the optimizer used the entire

partial arc trajectory, and RA_avoid, where sectors (set

from ~0 to ~105 degree) of MU=0 were set. Common dose

objectives included a stringent dose homogeneity, mean

dose to heart <5Gy, ipsilateral lung <8Gy, contralateral

lung <2Gy, contralateral breast <3Gy.

Results

RA_full showed a better dose conformity, lower high dose

volumes in healthy tissue and lower skin dose. The NTHD

(normal tissue high dose, defined as the uninvolved tissue

receiving 90% of the dose prescription relative to the

volume of the target) resulted in 18% and 31% for RA_full

and RA_avoid, respectively. RA_avoid presented a

reduction of the mean doses for all critical structures: 51%

to heart, 12% to ipsilateral lung, 81% to contralateral lung,

73% to contralateral breast. All differences were

significant with p<0.0001.

Conclusion

The adaptation of VMAT options to planning objectives

reduced significantly the healthy tissue dose levels at the

price of some high dose spillage. Evaluation of the trade-

offs to apply to the different critical structures should

drive in improving the usage of the VMAT technique for

breast cancer treatment, as the choice of the trade-offs

would affect the possible future late toxicity and

secondary cancer induction risk.

EP-1561 Comparison of heart, lung doses, and skin

toxicity from different breast cancer RT techniques.

M. Lizondo

1

, N. Jornet

2

, M.J. Fuentes-Raspall

3

, P.

Carrasco

2

, A. Latorre-Musoll

2

, A. Ruiz-Martinez

2

, T.

Eudaldo

2

, P. Delgado-Tapia

2

, C. Cases

2

, M. Ribas

2

1

Institut de Recerca Hospital de la Santa Creu i Sant Pau,

Servei de Radiofíosica i Radioprotecció, Barcelona, Spain

2

Hospital de la Santa Creu i Sant Pau, Servei de

Radiofísica i Radioprotecció, Barcelona, Spain

3

Hospital de la Santa Creu i Sant Pau, Servei d'Oncologia

Radioteràpica, Barcelona, Spain

Purpose or Objective

The aim of this study was to assess whether there are

significant differences in lung and heart doses for

different breast cancer radiotherapy techniques. This

study is based on a plan comparison from the dosimetric

and patient data prospectively collected in a breast RT

treatment database. Patient and treatment risk factors

for acute skin toxicity were analysed.

Material and Methods

Patient, treatment variables and treatment-related

outcomes were abstracted for 469 breast cancer patients

who completed radiotherapy treatment from 2013 to

2016. We selected patients with similar nominal dose to

the whole breast (50 Gy) and to the boost (EQD2 66 Gy),

patients with no electron boost were excluded. We also

included

patients

with

lymph

nodes(LN),

irradiation(50Gy). The available techniques were 3DCRT

and IMRT and from April 2016 onwards, deep inspiration

breath hold (DIBH) is used for all left breast patients.

Following our technique decision criteria, all boost areas

deeper than the range of our highest e- energy, are

treated with integrated boost using IMRT. And till 2016,

left breast cancer patient not fulfilling heart and/or lung

dose restrictions with 3DCRT were moved to IMRT. For

each patient, the technique was chosen in order to

maximize PTV coverage and homogeneity while keeping

doses to OAR as low as possible.

Heart dose (D

mean

,V

25

) and the ipsilateral lung dose (V

20

)

values were compared separately as a function of

laterality for patients undergoing 3DCRT (with and without

DIBH) or IMRT. Correlation tests were made between

maximum acute skin toxicity and technique, season, skin

photo-type, breast volume and smoking habits.

Results

Table I shows mean values and significance results. For

right-sided breast patients, heart D

mean

was significantly

lower for 3DCRT techniques than for IMRT techniques,

while heart V

25

and lung V

20

are not significantly different.

For left-sided breast patients heart D

mean

was lower but

heart V

25

was higher with the 3DCRT techniques than with

IMRT techniques when LN were not included, and heart

D

mean

also when LN were included. Lung V

20

was not

significantly different. For those patients treated with

DIBH, heart D

mean

and heart V

25

were considerably lower.

Skin toxicity shows a significant correlation with breast

volume (p=0.01) but not with technique, smoking habits,

skin photo type or period of the year in which the patient

was treated.