Table of Contents Table of Contents
Previous Page  415 / 596 Next Page
Information
Show Menu
Previous Page 415 / 596 Next Page
Page Background

(NC). A 20 µL aliquot was transferred to the NC and the Reagent Control (RC) tubes. A 20 µL

1

aliquot of a randomly picked sample was added to the Matrix Control tube, mixed, and recapped.

2

Using the 3M

software, prompts were followed to identify samples and controls. All samples

3

were loaded into the Speed Loader Tray, placed into the Molecular Detection System, and the

4

3M

MDA 2 -

Listeria

assay was initiated and results were obtained within 75 minutes.

5

6

Matrix Study Results

7

8

For each method, the probability of detection (POD) was calculated as the number of positive

9

outcomes divided by the total number of trials. [13] The following were calculated: the candidate

10

presumptive results, POD

CP

;

the candidate confirmatory results, POD

CC

; the difference in the

11

candidate presumptive and confirmatory results, dPOD

CP,

; the presumptive candidate results that

12

confirmed positive, POD

C

(=POD

CC

);

the reference method, POD

R

, and the difference in the

13

confirmed candidate and reference methods, dPOD

C

. POD analyses were conducted for the

14

MDA 2 -

Listeria

test points and compared to the appropriate reference method results. The pre-

15

validation target analyte background screen results and APC results are presented in Table 5. The

16

heat stress data for selected matrixes are presented in Table 6. The inoculum levels for each

17

environmental surface are presented in Table 7. A summary of POD analyses [14] are presented

18

in Tables 8-15. As per criteria outlined in Appendix J of the Official Methods of Analysis

19

Manual [15], fractional positive results were obtained for all matrixes.

20

21

Internal Study

22

23

Raw chicken leg pieces (25 g)

24

25

For the low inoculation level of the MDA 2 -

Listeria

assay, there were 4 presumptive positives

26

and 9 confirmed positives following the USDA/FSIS MLG 8.09 reference method confirmation

27

procedure resulting in 5 false negative samples. There were 5 observed positives for the

28

reference method. For the high inoculation level, there were 3 presumptive positives and 3

29

confirmed positives following the USDA/FSIS MLG 8.09 reference method confirmation

30

procedure. There was 1 confirmed positive following the reference method. Even though 5 false

31

negatives were confirmed, analysis show there to be no statistical difference when compared to

32

the reference method. Detailed results of the POD analyses are presented in Tables 8 and 12.

33

This matrix analysis was conducted using Demi Fraser with FAC brand X.

34

35

Raw chicken fillet (25 g)

36

37

For the low inoculation level of the MDA 2 -

Listeria

assay, there were 4 presumptive positives

38

and 4 confirmed positives following the USDA/FSIS MLG 8.09 reference method confirmation

39

procedure. There were 5 observed positives for the reference method. For the high inoculation

40

level, there were 2 presumptive positives and 2 confirmed positives following the USDA/FSIS

41

MLG 8.09 reference method confirmation procedure. There were 5 confirmed positives

42

following the reference method. Detailed results of the POD analyses are presented in Tables 8

43

and 12. This matrix analysis was conducted using Demi Fraser with FAC brand Z.

44

45

46