Previous Page  27 / 155 Next Page
Information
Show Menu
Previous Page 27 / 155 Next Page
Page Background

General Standards

Architecture & MEP Standards

Engineering & Energy Standards

Environmental Standards

Survey Standards

REVIT

GIS

Microstation



Reference type:

Overlay

(as opposed to "Attachment" type)

Prevents the xref from tagging along as a nested xref when the host drawing is referenced by another file.

Best method is to choose this type when you initially attach the reference

If you forget and attach it as an "Attachment" type reference, you can change it afterward in the Xref

Manager.



File path type:

No Path

– Preferred or if necessary can use Relative (which is "partially specified

folder path that assumes the current drive letter or folder of the host drawing") Full path is only allowed when

a reference to another project is required.

Best method is to choose this type of attachment when you initially overlay the reference

Helps to prevents loss of xref data when drawing is moved to a different location (examples: record\out or

outside BL)

Prevents drawing from accidentally reading the xref from an unintended location.



Binding of References

Unless otherwise instructed to by a client, NEVER bind any external reference (xref) into other files. Doing so

generates a large MESS of un-needed information that is difficult to manage on the working drawing and the

workflow downstream. Please coordinate within your department on the need. If in question, use E-transmit and

let the recipient manage the packaged data as they require.

+ TEMPLATES

Template drawing files can be found in the following

location:

F:\CADD\Templates\ARCH

> > >

Page 4

//

Section 2

Xref Standards