Installation
7
Mounting sensing element inside a pipe is not recommended.
Do not mount a Cote-Shield sensing element through a nozzle
that exceeds length of first insulator.
Ensure that there are no obstructions or agitator blades to
interfere with sensing element.
Rigid sensing elements can be mounted either vertically or
horizontally.
Figure 2-2
Installation Considerations
NOZZLE
NOZZLE
Wall build-up
does not extend
past first
insulator.
Cote-shield must
extend through
nozzle and wall
build-up.
Wrong
Nozzle too long;
Cote-shield too short.
Factory-supplied Cote-shield
extends through nozzle and
wall build-up.
Best
Best
No Nozzle
Good
Long Nozzle
2.2
Mounting and Installation Guidelines (Continued)
Do Not Shorten the sensing element without
checking with the factory. 1-800-527-6297 or
215-674-1234