Safety IntelliPoint RF, SXRNTXX Series User's Manual

20

Figure 4-4

Testing Power Supply

Common

data

- 5

NC

NC

+ 5

Power Supply Voltages

NO CONNECTION

OHMMETER

CENTER - GROUND

CENTER - SHIELD

SHIELD - GROUND

OHMS

OHMS

OHMS

CORRECT READING = OPEN CIRCUIT

CHECK FOR SHORTS

8

0

8 8 8

Figure 4-3

Testing Remote Cable

SHORT OUT

TWO CONDUCTORS

CENTER - GROUND

CENTER - SHIELD

SHIELD - GROUND

OHMS

OHMS

OHMS

SHORTED WIRES SHOULD READ 0 OHMS

CHECK FOR CONTINUITY

8

0

"0"

"0"

"0"

OHMMETER

4.6

Testing Remote Cable

4.7

Testing Power Supply

Power supply can be tested separately as follows:

1. Remove power from electronic unit.

2. Remove three screws holding circuit board into housing.

3. Disconnect sensing element connection.

See to Section 2.7

Sensing Element Connection

.

4. Reapply power.

5. Using a DC voltmeter, measure voltage from -5 to Common

and +5 to Common. Correct readings are -5 to -6 and +5 to

+6 Vdc.

See Figure 4-4

.

Sensing Element

Circuits Side