Edition 47 16-59

Hydraulic

Mining Shovels

16

Specifications

Front Shovel Configurations with Electric Drive

MODEL

6050 AC FS

6060 AC FS

6090 AC FS

Total Output

1600 kW

1800 kW

3200 kW

OperatingWeight

515 100 kg

1,135,590 lb

546 300 kg

1,204,370 lb

955 000 kg

2,105,410 lb

Electric MotorType:

Squirrel cage

induction motor

Squirrel cage

induction motor

Squirrel cage

induction motor

Number of Motors

1

1

2

Standard Voltage*

6.6 kV ± 10%

6.6 kV ± 10%

6.6 kV ± 10%

Rated Current I

N

(at standard voltage)

174 A

194 A

332 A

Standard Frequency*

50 Hz

50 Hz

50 Hz

Standard Revolutions*

1500 RPM

1500 RPM

1500 RPM

Starting Current (direct start)

350% of I

N

350% of I

N

780 A

Starting Current (soft start, optional)

197% of I

N

197% of I

N

N/A

Maximum Hydraulic Pump Output at Rated RPM:

Implement

4 ×

933 L/min

4 ×

246 gpm

4 ×

933 L/min

4 ×

246 gpm

8 ×

943 L/min

8 ×

249 gpm

Swing

3 ×

491 L/min

3 ×

131 gpm

3 ×

491 L/min

3 ×

131 gpm

6 ×

496 L/min

6 ×

131 gpm

Maximum Swing Speed

4.0 RPM

4.0 RPM

4.1 RPM

MaximumTravel Speed at Standard RPM:

Low

1.6 km/h

0.99 mph

1.4 km/h

0.87 mph

1.4 km/h

0.9 mph

High

2.3 km/h

1.44 mph

2.7 km/h

1.68 mph

1.9 km/h

1.2 mph

*Other voltages and frequencies like 7.2 kV/60 Hz are available on request.

NOTE:

Other specifications of the diesel driven shovels remain unchanged.