30-16 Edition 47
Tables
ALTITUDE DERATION (Continued)
MODEL
0-760 m 760-1500 m 1500-2300 m 2300-3000 m 3000-3800 m 3800-4600 m
(0-2500') (2500-5000') (5000-7500') (7500-10,000') (10,000-12,500') (12,500-15,000')
R1300G†
100
100
100
100
100
100
R1600H
1
†
100
100
100
100
100-97
97-94
R1600H (VR)^†
100
100
100-99
99-94
94-88
88-81
R1700G
1
†
100
100
100
100
100-95
90
R1700G (VR)^†
*
*
*
*
*
*
R2900G
1
†
*
*
*
*
*
*
R2900G (VR)^†
100-99
99-98
98-98
98-97
97-90
90-81
R3000H
1
†
*
*
*
*
*
*
R3000H (VR)^†
100-99
99-98
98-98
98-97
97-90
90-81
AD30
1
†
100
100
100
100
100-97
90
AD30 (VR)^†
100
100
100
100
100-97
90
AD45B
1
†
100
100
100
100-97
97-91
83
AD55
1
†
*
*
*
*
*
*
AD60†
*
*
*
*
*
*
6015B
2
◀
100
100
100
100
100-98
98-97
6015B
3
100
100
100
100
100
100-99
6020B
◀
100
100
100
100
100-99
99-98
6030/6030 FS
◀
100-99
99-89
89-82
82-76
76-72
72-69
6040/6040 FS
◀
100
100
100
100-96
96-87
87-79
6050/6050 FS
4
100
100
100
100-90
90-78
78-64
6050/6050 FS
5
◀
100
100
100
100
100
93-83
6060/6060 FS
◀
100
100
100
100
100
96-87
6090 FS
6
◀
100
100
100
100
100
100
1
Meets Tier 3/Stage IIIA/Japan 2006 (Tier 3) equivalent emission standards.
2
MeetsTier 4 Final/Stage IV/Japan 2014 (Tier 4 Final) emission standards.
3
MeetsTier 1/Stage I ORTier 2/Stage II/Japan 2001 (Tier 2) equivalent emission standards.
4
K1500E engines, derating is based on a different rating methodology at lower ambient temperatures.
5
QSK38 engines, derating is based on a different rating methodology at lower ambient temperatures.
6
QSK60 engines, derating is based on a different rating methodology at lower ambient temperatures.
*
*Information not available at time of printing.
◀
Automatic altitude deration.
*
^Ventilation Reduction engine option.
*
†Assumes ambient air temperature of 25° C
(77° F
).
NOTE:
Derates are reported as a percentage of power and highlights the change from the start to the end elevation in a given column. Contact factory for
deration estimates based upon site specific temperatures and altitudes.