Table of Contents Table of Contents
Previous Page  444 / 696 Next Page
Information
Show Menu
Previous Page 444 / 696 Next Page
Page Background

Accuracy

Accuracy was tested by spiking (fortifying) with varying concentrations of choline or

carnitine in a variety of SPIFAN materials that would best encompass the different types

of products and cover the analytical range of the method. Recovery was tested in both

the free and total analyses. Recovery towards the SMPR LOQ can be found in Tables 2

and 3. A high fat RTF adult nutritional was spiked with choline to achieve the upper

SMPR range for total choline at 250 mg/100g (Table 16). The other products chosen for

spike recovery were the SPIFAN Blank milk based RTF infant formula, soy based

powder infant formula, and a high protein RTF adult nutritional (Tables 17-22). Each

product had endogenous levels of choline and carnitine, so 50 and 100% overspikes were

utilized to assess recovery. Each of the products were spiked in duplicate across three

days using multiple analysts. The marginal recovery (recovery of spiked amount) plus

total recovery (recovery of endogenous + spiked amount) are provided in these tables due

to the variability that can be encountered when spiking much less than the endogenous

amount. Outliers were not removed from the recovery analysis and calculations used all

recovery results. The mean recoveries obtained meet the SMPR requirements over the

analytical ranges required. Another assessment of the total analysis was performed to

determine the efficiency of hydrolyzing bound forms of carnitine and choline. Raw

materials of acetylcarnitine, acetylcholine, and phosphatidylcholine were tested through

the total analysis at levels that would be at the upper range of the SMPR (Table 23).

Acetylcholine and acetylcarnitine showed recoveries over 100% that indicated complete

hydrolysis of these forms. Nominal purities for the raw material provided by the

manufacturer were used to calculate the recoveries. Although the recovery analysis of

these materials may not be the most accurate, it still is good indication that these forms

are being completely hydrolyzed through the method. The phosphatidylcholine showed

more variable recoveries, but the overall mean recovery verifies an almost complete

hydrolysis of this bound form. NIST SRM 1849a was also analyzed over four days in

triplicate and results obtained meet the certified ranges or fall close to the informational

mass fraction value given. The carnitine certified range is understood as free carnitine

and not total carnitine. The SRM showed an increase in the total analysis from the free

analysis, which indicates the presence of bound forms of carnitine in the SRM.

Chol-08/Carn-07 (February 2016)

FOR ERP USE ONLY

DO NOT DISTRIBUTE