ESTRO IMRT course 2015

Dose Calculation in Static and Rotational IMRT

Brussels October 8th, 2015

-49-

Dose calculation issues ‚in practice‘

Some examples for situations which need special care:

small fields, irregular shaped fields (esp. off-axis), …

potential systematic errors in measured base-data

air in rectum

dose calculation in lung in presence of breathing motion (‘4D’ dose)

dose absorption in the patient table/couch

dose calc in presence of CT artifacts: dental&hip implants

HU errors in CT-calibration

Even when using allegedly ‘precise’ dose calculation algorithms:

DON’T TRUST YOUR DOSE TOO MUCH!