INSTRUMENT/ELECTRICAL CABLE SCHEDULE
CABLE
CONDUCTORS
CABLE ROUTE
APPROX.
REMARKS
REFERENCE TYPE AREA No.
FROM
GLAND
TO
GLAND LENGTH
mm
2
TYPE
TYPE
METRES
CP2/FS88
J2
1.5
2 CP2 Panel
Safe Area FS88 MCC
Safe Area
10
CP2/FS89
J2
1.5
2 CP2 Panel
Safe Area FS89 MCC
Safe Area
10
CP2/BJB09
J27
1.5
27 CP2 Panel
EEx 'de'
BJB09 Road Loading Pump Junction Box
EEx 'de'
100
J88A/BJB09
J4
1.5
4 BJB09 Road Loading Pump Junction Box
EEx 'de'
J88A Stop/Start Station
EEx 'de'
10
TP88/BJB09
J2
1.5
2 BJB09 Road Loading Pump Junction Box
EEx 'de'
TP88 Temperature Switch
EEx 'de'
10
BJB09/CP3
J27
1.5
27 BJB09 Road Loading Pump Junction Box
EEx 'de'
CP3 Gantry Control Unit
EEx 'de'
100
J89A/CP3
J4
1.5
4 CP3 Gantry Control Unit
EEx 'de'
J89A Stop/Start Station
EEx 'de'
20
TP89/CP3
J2
1.5
2 CP3 Gantry Control Unit
EEx 'de'
TP89 Temperature switch
EEx 'de'
20
FIR5/CP3
J2
1.5
2 CP3 Gantry Control Unit
EEx 'de'
FIR5 Eexd Horn
EEx 'de'
20
SOL12/CP3
J2
1.5
2 CP3 Gantry Control Unit
EEx 'de'
SOL12 - Solenoid Valve in Pneumatic Panel
EEx 'de'
20
EP2/CP3
J2
1.5
2 CP3 Gantry Control Unit
EEx 'de'
EP2 Scully
EEx 'de'
20
RG2/CP2
J3
1.5
3 RG2 ENRAF Control Unit
EEx'de'
CP2 Panel
EEx 'de'
200
BJB10/RG2
F2
1.5
2 pair BJB10 ENRAF Junction Box
EEx'de'
RG2 ENRAF Control Unit
EEx 'de'
20
TOTAL
560
Note : Refer to P&I Design Cable Specifications for details on Cable Type.
REFERENCE DRAWINGS
REV DATE BY DRN
CHK'D
APP'D
DESCRIPTION
PLANT
Simon Storage - Tyne Terminal
A 07/10/97 AS AS DRR DRR DRR DRR ORIGINAL ISSUE
TITLE
Fluorobenzene Tank 24 - 24V DC Cables
B 13/10/97 AS AH DRR
DRR
240V DB Revised
SHEET 2 OF 3
CLIENT DRG No
REF NO SI347100.SCH