AIR CONDITIONING

Lubrication

and Leak Detection

1.2

UV and electronic leak detection

According to the Kyoto Protocol, it is forbidden to refill an A/C loop if it is

leaking. A thorough leak diagnosis must be performed.

Valeo offers two solutions:

UV leak detection and electronic leak detection.

Ref.

699934

Ref.

710075

Dye cartridge 240 ml

Ref.

710064

Single Dose Leak Detection Kit

6 x 7.5 ml dye cartridges

+ Injection Gun + Coupling

Ref.

699932

Leak Detection Kit - 240 ml dye

cartridge + Injection Gun + Coupling

Ref.

710065

6 x 7.5 ml dye cartridges

Ref.

710067

Dye cleaner for UV Dye after

inspection

UV leak detection

Electronic leak detection

Detected gas

R12/R22/R134A

Detection type

Heated pentod

R12 sensitivity

1.4 g/year

R134a sensitivity

< 3g/year

Sensitivity levels

2

Response time

2 second

Alarm type

Visual/audible

Operating temperatures 0-50° C

Weight

452 g

Nicad

rechargeable

Sensor lifetime

100-150 h

Ref.

625081

Fluorescent Dye HYBRID (250 ml)

Ref.

625082

Fluorescent Dye HYBRID in Syringe (7,5 ml + HOSE)

Ref.

625083

Fluorescent Dye HFO 1234yf in Syringe (75 ml + HOSE)

Ref.

625084

Fluorescent Dye Remover trigger (250 ml)

Ref.

710237

UV Dye for HFO 1234yf

Ref.

710204

UV Lamp kit: Lamp + Glasses

Ref.

625087

Nitrogen/Hydrogen Leak detector kit

Ref.

625088

Nitrogen/Hydrogen Cylinder

25