HOW A/CWORKS

Air conditioner components are connected

together to illustrate system operation. The

components shown are not to scale. The

refrigerant and refrigerant oil are clear in color

and not visible in this drawing; however, we've

attempted to suggest temperature variants

through the use of values of gray in the pipeline.

The small arrows inside the components

and connecting hoses show the direction of

refrigerant flow (refrigerant circuit).

TYPICAL PLUMBING SCHEMATIC

LOWSIDE HIGH SIDE

WARM

INLET

AIR

COOL

OUTSIDE

AIR FLOW

HEATED

OUTSIDE

AIR FLOW

COOL

AIR TO

THE CAB

#12 Hose

Gas

17-30 PSI

#6 Hose

Liquid

#8 Hose

Gas

#8 Hose Gas

300 PSI

#8 Hose Gas

#6 Hose Liquid 135°

#8 hose

Liquid 200°

Thermostat

High

Pressure

Liquid

Metered

Refrigerant

Cold,

Low Pressure

Gas

Low Pressure Gas

(suction side)

Hot High

Pressure Gas

Receiver

Drier

Expansion

Valve

Evaporator

Condenser