Model R-8820/8150

HEATERS AND

AIR CONDITIONERS

TECHNICAL SALES BULLETIN AND SERVICE PARTS LIST

RD-3-8266-0 (REV -–)

DIMENSIONS

SPECIFICATIONS

BTU's:

Air Flow:

Weight:

Current Draw:

Heating - 27,000 BTU/Hr @ 100

°

F

(6,804 kcal/h @ 37.8

°

C) Air Temp Rise

Cooling - 20,000 BTU/Hr @ 36

°

F (5,040 kcal/h @ 2.2

°

C)

Refrigerant Temp and 80

°

F (26.7

°

C) Wet Bulb Entering Air

250 CFM (425 m

3

/h)

34 Lbs (15 Kg)

14 Amps @ 13.6 VDC

SCHEMATICS

PLUMBING SCHEMATIC

ELECTRICAL SCHEMATIC

17.9 in.

(45.5 cm)

12.1 in

(30.3 cm)

13.9 in

(35.3 cm)

32.5 in.

(82.6 cm)

8.5 in

(21.6 cm)

10 in

(25.4 cm)

1 in

(2.6 cm)

14.1 in

(35.8 cm)

Rec/Drier

Expansion

Valve

Compressor

#8 High Pressure

#10 Suction

To

Condenser

#6 Liquid

#6 High

Pressure

From

Condenser

MICRO

SWITCH

LIGHT

RESISTOR

FAN

SWITCH

THERMOSTAT

WHT

WHT/BLK

BLK

WHT

BLK

WHT

BLK

BLK

YEL

14 GA. ORG

14 GA. RED

14 GA. ORG

14 GA. RED