Previous Page  21 / 28 Next Page
Information
Show Menu
Previous Page 21 / 28 Next Page
Page Background

21

www. 3 g t t p . c om

Volvo

Primary Applications: FH16

Euro 6

# Description

OEM Ref.

Racor Ref.

3G Ref.

1 FFWS assembly,

electric pump, with AHI

21762800

DRK00431

TN0555

1 FFWS assembly,

manual pump, with AHI

21762764

DRK00432

TN0310

1 FFWS assembly,

manual pump, without AHI

21879911

DRK00405

TN0360

2a Replacement element -

primary filter

21764966 (standard life)

21764964 (long life)

R60RDRCR01

R60RDRCR01

TN0320

TN0320

2b Replacement element -

primary filter (ultra life)

21764964

R90RDRCR01

TN0390

3 Bowl assembly

21762862

DRK00407

TN0365

4a Replacement element

- secondary filter

21764952

RS175RCR01

TN0395

4b Replacement element

- secondary filter

21764937

RS250RCR01

TN0085

-

Priming pump kit

22502434

DRK00489

*Special Order

-

Pressure sensor

Racor exclusive

DRK00491

*Special Order

-

Connector 8.0mm

21762883

DRK 00289-RCR *Special Order

-

Connector 10.0mm

21762881

DRK 00288-RCR *Special Order

-

Connector 12.0mm

21762877

DRK 00287-RCR *Special Order

-

AHI unit

21762848

DRK00515

*Special Order

-

Bowl assembly

21762862

DRK00516

*Special Order

-

Bowl clip

21762885

DRK00517

*Special Order

Fuel

1

1

2

2

3

3

4

4

5

5

6

6

A

A

B

B

C

C

D

D

A

MATERIAL:

DRAWN

CHECKED

APPROVED

Sam Lucking

ParkerHannifinManufacturing (UK) Ltd.

FilterDivision Europe

Shaw Cross Business Park

Dewsbury

West Yorkshire

WF12 7RD

A0

03/09/2015

DATE

NAME

N/A

PROJECT CODE:

1 of 1

GENERAL TOLERANCE TO EN ISO 2768-mUNLESS STATED

FINISH:

1 : 0.5

TITLE:

DRAWINGNO:

-

-

euro6-working

MASS

SCALE

SHEET

REV

THISDOCUMENTCONTAINS INFORMATIONTHAT IS

CONFIDENTIALANDPROPRIETARYTOPARKERHANNIFIN

MANUFACTURING (UK)LTD. THISDOCUMENT ISFURNISHED

ONTHEUNDERSTANDINGTHATTHEDOCUMENTANDTHE

INFORMATION ITCONTAINSWILLNOTBECOPIEDOR

DISCLOSEDTOOTHERSORUSEDFORANYPURPOSEOTHER

THANCONDUCTINGBUSINESSWITHPARKER,ANDWILLBE

RETURNEDANDALLFURTHERUSEDISCONTINUEDUPON

REQUESTBYPARKER. THERECIPIENTOFTHISDOCUMENT

THROUGH ITSOWNANALYSISANDTESTING ISSOLELY

RESPONSIBLEFORMAKINGTHEFINALSELECTIONOFTHE

APPLICABLESYSTEMANDCOMPONENTSANDASSURING

THATALLPERFORMANCE,ENDURANCE,MAINTENANCE,

SAFETYANDWARNINGREQUIREMENTSOFTHEAPPLICATION

AREMET.COPYRIGHTPARKER.YEAROFCOPYRIGHT ISFIRST

YEAR INDICATEDONTHISDOCUMENT. ALLRIGHTS

RESERVED.

©

A

Sam

Luckin

g

REV

DESCRIPTION

ECNNO

DATE

DRN

CHK

4

1

2

3