4 fractions of BT with 7Gy fraction size, in 2 applications in consecutive weeks
Planning with
Oncentra GYN
treatment planning system (Nucletron)
1
st
application
2
nd
application
MRI-
based planning:
3D applicator reconstruction
target delineation
OAR delineation
Dose planning and optimization
CT-
based planning:
3D applicator reconstruction
Automatic target transfer from 1
st
MRI via applicator-based image
registration
OAR delineation
Dose planning and optimization
Combined MRI-/CT- guided BT for cervical cancer
Nesvacil et al. 2014