Table of Contents Table of Contents
Previous Page  943 / 1228 Next Page
Information
Show Menu
Previous Page 943 / 1228 Next Page
Page Background

Further reading …

References cited in this lecture:

•Adolfsson, E. et al., 2010. Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy. Med. Phys., 37(9), p.4946.

•Aldelaijan, S., Mohammed, H., Tomic, N., Liang, L.-H., Deblois, F., Sarfehnia, A., … Devic, S. (2011). Radiochromic film dosimetry of HDR (192)Ir source radiation

fields. Medical Physics, 38(11), 6074–83.

•Araki, F. et al., 2013. Measurement of absorbed dose-to-water for an HDR (192)Ir source with ionization chambers in a sandwich setup. Med. Phys., 40(9), p.092101.

•Brown, T. a D., Hogstrom, K. R., Alvarez, D., Matthews, K. L., Ham, K., & Dugas, J. P. (2012). Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to

synchrotron-produced monochromatic x-ray beams. Medical Physics, 39(12), 7412–7.

•Chiu-Tsao, S.-T., Medich, D. & Munro, J., 2008. The use of new GAFCHROMIC EBT film for [sup 125]I seed dosimetry in Solid Water phantom. Med. Phys., 35(8),

p.3787.

•Davis S D Ross C K Mobit P N Van der Zwan L Chase W J & Shortt K R (2003) The response of lif thermoluminescence dosemeters to photon beams in

, . .,

, . .,

, . .,

, .,

, . .,

, . .

.

the energy range from 30 kV x rays to 60Co gamma rays. Radiation Protection Dosimetry, 106(1), 33–43.

•Devic, S. (2011). Radiochromic film dosimetry: past, present, and future. Physica Medica : PM : An International Journal Devoted to the Applications of Physics to

Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (AIFB), 27(3), 122–34.

•Kennedy, R. M., Davis, S. D., Micka, J. A., & DeWerd, L. A. (2010). Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model

9011 THINSeed brachytherapy source. Medical Physics, 37(4), 1681–8.

•Kolbun, N. et al., 2010. Experimental determination of the radial dose distribution in high gradient regions around 192Ir wires: comparison of electron paramagnetic

resonance imaging, films, and Monte Carlo simulations. Med. Phys., 37(10), pp.5448–55.

•Luxton, G. (1999). Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study.

Medical Physics, 21(5), 631.

•Nunn, A. A., Davis, S. D., Micka, J. A., & Dewerd, L. A. (2010). LiF : Mg , Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the

range of 20 – 250 kVp relative to C 60 o LiF : Mg Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 1859(2008)

  ,

,

.

•Palmer, A.L. et al., 2013. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber,

EBT3 Gafchromic film, and PRESAGE® radiochromic plastic. Med. Phys., 40(6), p.061707.

•Palmer, A.L., Lee, C., et al., 2013. Design and implementation of a film dosimetry audit tool for comparison of planned and delivered dose distributions in high dose rate

(HDR) brachytherapy. PMB, 58(19), pp.6623–40.

•Palmer, A.L., Nisbet, A. & Bradley, D., 2013. Verification of high dose rate brachytherapy dose distributions with EBT3 Gafchromic film quality control techniques. PMB,

58(3), pp.497–511.

•Papagiannis, P., Pantelis, E., Georgiou, E., Karaiskos, P., Angelopoulos, A., Sakelliou, L., … Seimenis, I. (2006). Polymer gel dosimetry for the TG-43 dosimetric

characterization of a new 125I interstitial brachytherapy seed. PMB,

51

(8), 2101–11.

•Patel, N. S., Chiu-Tsao, S.-T., Williamson, J. F., Fan, P., Duckworth, T., Shasha, D., & Harrison, L. B. (2001). Thermoluminescent dosimetry of the SymmetraTM [sup

125]I model I25.S06 interstitial brachytherapy seed. Medical Physics, 28(8), 1761.

•Sarfehnia A Kawrakow I & Seuntjens J 2010 Direct measurement of absorbed dose to water in HDR [sup 192]Ir brachytherapy: Water calorimetry ionization

, .,

, .

, .,

.

,

chamber, Gafchromic film, and TG-43. Med. Phys., 37(4), p.1924.

•Schaeken, B. et al., 2011. Experimental determination of the energy response of alanine pellets in the high dose rate 192Ir spectrum. PMB, 56(20), pp.6625–34.

•Tedgren, A. C., Hedman, A., Grindborg, J.-E., & Carlsson, G. A. (2011). Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the

dosimetry of brachytherapy (<1 MeV). Medical Physics, 38(10), 5539–50.

•Tello, V. M. (1995). How water equivalent are water-equivalent solid materials for output calibration of photon and electron beams? Medical Physics, 22(7), 1177.