Examples for hypofractionation schedules

in Brachytherapy

Cervix:

o

4 x 7 Gy

o

2 x 9 Gy

Bronchus: 4 x 7.5 Gy

Breast:

o

APBI:

8 x 4 Gy, 6 x 6 Gy

o

Boost:

1 x 10Gy

Prostate: up to 20 Gy in 1 fraction