ROUND UP

New-generation, high-performance thermal imaging cameras

The

Comtest Group

, Fluke’s authorised Test and

Measurement Distributor for South and southern

Africa, has introduced a trio of new Fluke high-

definition, industrial-performance digital cameras,

theTi400,Ti300 andTi200. Equipped with LaserSharp

Auto Focus, while not new technology, Fluke has

taken it a step further, guaranteeing perfectly focused

images, every time.

Users of infrared camera technology, rate focus as

the single most important factor when conducting

an infrared inspection. Without an in-focus image,

temperature measurements are not accurate and

problems could be overlooked. LaserSharp auto fo-

cus technology on these Fluke IR cameras, indicates

exactly where the focal point is by using a laser to

calculate the distance to the target, before it

focuses. It simply requires that the user places a

red laser dot on the equipment to be inspected,

the trigger is then pulled and released, delivering

a perfectly focused image.

TheTi 400 range features wireless connectivity

enabling the cameras to connect with other wire-

less devices. Free firmware allows for the capture

of up to five additional measurements with the

CNXWireless system directly a PC, Apple iPhone

or iPad. These additional measurements help

diagnose problems faster and provide additional

data to create more comprehensive reports.

Enquiries:Tel. 010 595 1821 or email

sales@comtest.co.za

or visit

www.comtest.co.za

New ultrasonic water meter for

instantaneous measurements

Instrotech

representing ELIS, manufacturer and supplier of

flowmeters, has launched a battery-powered ultrasonic wa-

ter meter intended for measuring flow rate instantaneously

and pressure and consumption in water piping (standard EN

14154 for water works), water distribution systems and other

industrial applications. The compact, highly accurate ELIS

FLOMIC FL5024 has long-term stability over a wide range

of measured values, and conforms to the IP68 class (Ingress

Protection… classifies and rates the degree of protection

provided against intrusion). The meter does not need any

external power supply, does not include any moving parts

and has significantly lower hydraulic losses. The technical

parameters and other features of the FLOMIC water meter

make it suitable not only for water consumption measure-

ments but also for water-leak tracking and monitoring of the

general condition of water-supply networks where the meter

output signals can be connected via data transfer systems

to remote computer control stations.

The measurement method utilised by these meters is a

single-beam transit-time pulse method, based on evaluation

of the time needed for an ultrasonic signal to cross the dis-

tance between two measuring transducers. In the standard

version, the meter measures instantaneous flow rate (in

m3/hour) and the total volume of water passed through the

meter (in m3) in the given flow direction.The measured data

is converted into passive pulse output signals.

Enquiries: Instrotech.Tel. 010 595 1831 or

email

sales@instrotech.co.za

Ceramat retractable fittings for

process spectroscopy

Knick's Ceramat retractable fittings allow for a safe automatic clean-

ing of optical sensors without process interruptions and thus ensure

reliable process control. Featuring an inde-structible ceramic sealing

between sensor and process, Ceramat sensor lock-gates are suitable for

extremely demanding measuring tasks in various fields of applications,

where convention-al fittings fail. In addition, special Ceramat design is

compatible with Hellma sensors.The sensor can be directly immersed in

the stream. Measurements are no longer dependent on a conventional

immersion tube. UV/VIS/NIR and Raman spectroscopy are established

measuring technologies in process analysis. Optical immersion probes,

directly adapted to pipe or reactor, usually serve as inter-faces to the

process for these systems. Depending on the medium, however, the

optical win-dow can be contaminated, leading to a significant impairment

of measuring precision or even an altogether faulty measuring

signal.To

avoid this, measurement then has to be interrupted to cleanse the sensor

or put on hold until the next cleaning interval of the production facility.

Optical measuringmethods were therefore rarely used when dealing with

difficult mediums such as glue or moist powder.Working with Hellma and

tec5, Knick has solved this problem and specially adapted the tried-and-

tested Ceramat retractable fitting and the cleaning and calibration system

Unical 9000 to the requirements of spectroscopy with optical fibres and

optical immersion probes. Any contamination of the optical window is

detected by the spec-trometry software via the measuring signal. The

probe can then be cleaned when necessary or automatically accord-

ing to a set cycle. The

probe is rinsed with

up to four cleaning or

calibra-tion liquids and

dried with pressurized

air.

Mecosa

is the sole

agent for Knick Elektro-

nische Messgeräte in

Southern Africa.

Enquiries:Tel. 011

257-6100 or email

measure@mecosa.co.za

PRESSURE + LEVEL MEASUREMENT

Electricity+Control

January ‘16