Highly electrifying!

At the extrusion of cables their insulation

is inspected by spark testers (high-voltage

spark testers) and possible insulation

faults are detected and documented at an

early stage. With the new high-frequency

spark tester Spark 6030 HF, Sikora opens a

new chapter in the spark tester segment:

powerful, high reliability in the detection

of faults and intelligent multimedia

functions.

At the same time the Spark 6030 HF

underlines that reliable technology alone

is not sufficient to support the operator

considerably at work and to ensure safety.

That is the reason why Sikora has integrated

a 4-step function and safety test according

to EN61010-1:2010. Until now this had to

be performed by means of external testing

devices in the factory.

The Spark 6030 HF is developed for the

reliable detection of insulation faults in

cables with a diameter from 0.5 to 30mm.

The system reliably distinguishes between

punctual faults (pin holes) and bare patches.

For testing, the dry cable runs through

the sturdy bead chain electrode of the

spark tester. Typically the device is installed

after the cooling section. Here the cable

insulation is exposed to the specific test

voltage and faults in the insulation are

reliably detected.

Directly integrated in the device is a display,

visualising the selected test voltage, the

capacitive load and number of high-voltage

break downs. The display is combined

with a control panel for entering the test

voltage. For production lines without a line

computer the Spark 6030 HF is combined

with the processor controlled display and

control device Remote 2000.

According

to

European

standards,

measuring and testing equipment has to

be checked regularly. As an innovation in

the spark tester segment the Spark 6030 HF

optionally integrates a 4-step function and

safety test. Accordingly, the spark tester is

tested with regard to high-voltage, corona

level, short-circuit current and function

(sensitivity).

High-voltage test: In this test, the spark

tester checks the displayed high-voltage of

the device for correctness. The high-voltage

has to be within a tolerance of 5%.

Test of the short-circuit current: The spark

tester automatically checks the maximum

short-circuit current, which for a human

body model should not exceed 10 mA

when operating the device (according to

EN61010-1:2010).

Function (sensitivity) test: The spark tester

automatically performs a function test.

By means of an integrated spark gap 20

artificial faults (breakdowns) are initiated

in less than 20 seconds. The spark tester

automatically checks the correctness of fault

detection.

Corona test: The Spark 6030 HF

automatically measures and evaluates the

corona level. Within the creation of the test

certificate the corona level is documented.

Up to now, the operator was depending

on subjective and visual evaluation of

the condition of the insulators in order to

fulfil the requirements of EN61010-1:2010.

Worldwide the Spark 6030 HF is the only

spark tester that carries out this test.

Via Wi-Fi and smart phones, each test is

proved by a test certificate which is stored

and transmitted to quality management

with a single touch of the button. The

sparktester conforms to approved test

standards (AS, BS, CS, CENELEC, EN, UL, VDE)

and safety regulations (as demanded by

DIN/VDE 0800, IEC 479-1).

Sikora AG – Germany

Website

:

www.sikora.com