151

Table 5. Accuracy: recovery of SRM 1849a

SRM

product

Code

Reference

value, mg/kg

powder

Measured value,

mg/kg powder

Recovery versus

CoA, %

a

1849a CLC-10b

1.99

1.969

99

2.067

104

2.081

105

2.023

102

2.047

103

1.971

99

2.013

101

1.987

100

1.995

100

a

 CoA = Certificate of Analysis.

Table 6. Representative chromatograms of tested SPIFAN matrices

Matrix

SPIFAN Code

Chromatogram

Child Formula Powder, placebo

00847RF00

SRM 1849a

CLC10-b

Full-time range to include the riboflavin peak (

see

below)

Child Formula Powder

00866RF00

Specificity

.

Chromatograms from all of the SPIFAN

matrixes helped to establish the specificity of this method for

biotin.

See

Table 6 for representative chromatograms of tested

SPIFAN matrixes.

Ruggedness

.

Several parameters were varied during

validation to establish method ruggedness. Samples were

prepared by three analysts and analyzed with C18 columns from

four different lots. Fresh mobile phase, postcolumn reagents,

intermediate standards, and working standards were made daily

and used during validation.

Conclusions

The data presented in this paper were submitted to the AOAC

Expert Review Panel (ERP) for review at the AOAC Mid-Year

Meeting held on March 16, 2016. The ERP determined that the

data presented here were in accordance with SMPR 2014.005

(5) approved by SPIFAN, and the method was granted First

Action status.

References

(1) Deborde, J.-L., & Joseph, G. (2015)

J. AOAC. Int.

98

,

1044–1045,

http://dx.doi.org/10.5740/jaoac.int.SMPR2014.005

(2) Thompson, L.B., Schmitz, D.J., & Pan, S.-J. (2006)

J. AOAC

Int.

89

, 1515–1518

(3) Lahély, S., Ndaw, S., Arella, F., & Hasselmann, C. (1999)

Food

Chem.

65

, 253–258. doi:10.1016/S0308-8146(98)00185-X

(4) Höller, U., Wachter, F., Wehrli, C., & Fizet, C. (2006)

J. Chromatogr. B Analyt. Technol. Biomed. Life Sci.

831

, 8–16.

doi:10.1016/j.jchromb.2005.11.021

(5)

Official Methods of Analysis

(2016) 20th Ed., AOAC

INTERNATIONAL, Rockville, MD, SMPR 2014.005.

www.eoma.aoac.org