Charged Particle Equilibrium

only a fraction of electron track deposits

energy in voxel

A

dose is low

in voxel

B

, a new electron starts but there

is also part of electron track which started

upstream in voxel A

dose is higher B

kinetic energies leaving voxel C is balanced

by kinetic energies entering in this volume

equilibrium is reached at

C

at C

Dose ≈ KERMA

A B C

Charged particle equilibrium (CPE)

exists if for each charged particle with energy

E

leaving a volume

V

, there is an identical particle with same energy

E

entering

V

kV Xrays