Gas Valves, Pilot Controls, Safety Valves & Thermostats
360
This information is provided “as is” without warranty of any kind by any person,
including without limitation, the owner and the publisher.
Unit#2498049
36C Series
Replacement valves. 1/2 PSI maximum pressure rating and straight
through flow direction. Compatible with both LP and Natural gas.
No. 36C74-913.
Natural gas only.
GasValves,PilotControls,SafetyValves&Thermostats
Unit#2498049
36H Series
For use with intermittent ignition systems. Features adjustable regula-
tor, quiet operation, inlet/outlet screens and tamper resistant screws.
Compatible with LP and natural gas. 24V AC coil voltage.
Unit#2498049
Generates spark pulse until flame is sensed and begins sparking imme-
diately if flame extinguishes. Features solid-state module design.
Includes spark plug and 1/4” spade connectors. CSA approved.
Unit#2498049
For use with pipes 1/2” x 1/2”. Features straight
thru flow with plugged rear Inlet, (2) 1/2” x 3/8”
reducer bushings and thermocouple connection
opposite pilot.
Unit#2498049
750 Millivolt
For use with 750 mV self-genera-
tion control systems. Includes 36"
armored cable with split-spade ter-
minals, mounting nut, spring clips
and PG9 adapter sleeve.
Unit#2498049
Universal
Features stainless steel element construction, universal adapter fit-
tings, standard 11/32” double-lead thread and instructions.
GAS VALVES
Order
No.
Application
Coil
Voltage
PipeSize
In.
Opening
Snap Open, Single Function, Standing Pilot
36C03-300
Standing pilot
24VAC 1/2 x 3/4
Fast
36C03-333
Standing pilot
24VAC 1/2 x 3/4
Fast
36C03-400
Standing pilot
24VAC 3/4 x 3/4
Fast
36C03-433*
Standing pilot
24VAC 3/4 x 3/4
Fast
36C03U-333
Standing pilot
750mV 1/2 x 3/4
Fast
36C03U-433*
Standing pilot
750mV 3/4 x 3/4
Fast
HSI/DSI
36C74-913
Step open 24VAC 3/4 x 3/4
Step
36C94-303
Intermittent
systems ignition 24CAV 1/2 x 3/4 Delay slow
GAS VALVES
Order
No.
Pipe Size
In.
Opening
Stages
36H32-304
1/2 x 3/4
Fast
1
36H32-423
3/4 x 3/4
Fast
1
36H33-412
3/4 x 3/4
Slow
1
36H64-463
3/4 x 3/4
Fast
2
PILOT RELIGHT CONTROLS
Order
No.
Input Voltage
5059-23
24V AC
GAS PILOT SAFETY VALVES
Order
No.
Max. Pressure
PSI
764-742
1/2
POWER GENERATORS
Order
No.
Desc.
G01A-332
750 mV power
generator
THERMOCOUPLES
Order
No.
Lgth.
In.
H06E-24
24
H06E-36
36