Table of Contents Table of Contents
Previous Page  361 / 560 Next Page
Information
Show Menu
Previous Page 361 / 560 Next Page
Page Background

361

Generators, Temperature Controls & Relays

This information is provided “as is” without warranty of any kind by any person,

including without limitation, the owner and the publisher.

Chemicals

Charging,

Recovery

& Welding

Test Equip.,

Tools &

Service Acc.

Electrolux

& Frigidaire

GE

& Hotpoint

Whirlpool

& Maytag

Cooking

& Gas

Products

Dishwasher,

Disposer &

Water Heater

Laundry

Refrigeration

Fittings,

Venting &

Installation

Electrical

Plumbing

Property

Maintenance

HVAC/R

Motors

Unit#2498049

PG9

Provides pilot flame for igniting gas burners while generating millivolt

output to operate gas valves and relays. Features single-flame burner,

snorkel primary air path, flame ring surrounding generator and hightem-

perature stainless steel cover. Includes orifice base fittings for natural

and LP gas. 90° right porting. IAS certified.

Unit#2498049

Digital

For use with refrigeration and heating applications. Features alarm out-

put with selectable delay, -40°F to 220°F setpoint range and 1°F to

30°F differential range. Requires no common wire on uninterrupted

loads of 2.5A or greater.

Unit#2498049

Double Throw

For switching single- or two-speed fan motors, solenoids, relays, resis-

tive loads and other general purpose applications. Single pole, totally

enclosed. Contacts have inductive rating of 8A continuous, 25A inrush

@ 125/250V AC; resistive rating of 16A continuous @ 125/250V AC.

Unit#2498051

Heavy-Duty

Use with air conditioning, heating and general purpose switching appli-

cations. Operates in any position. Enclosed design. 24V Coil. Contacts

have inductive rating of 12A continuous, 60A inrush @ 125V AC; 8A

continuous, 48A inrush @ 250V AC. Resistive rating of 18A continuous

@ 277V AC.

Unit#2498050

Double Pole

Double-throw, semi-enclosed design. Easy to install and wire. Suitable

for vending machines, appliances, fan controls, heating and air condi-

tioning and general purpose switching applications. Power terminals.

Generators,TemperatureControls&Relays

PILOT GENERATORS

Order

No.

Head

PG9A42JTL20

Cobra

ELECTRONIC TEMPERATURE CONTROLS

Order

No.

Desc.

16E09-101

Electronic temperature control

ENCLOSED FAN RELAYS

Order

No.

Coil Voltage

@ 50/60Hz

90-293Q

24

ENCLOSED FAN RELAYS

Order

No.

Type

90-370

SPDT

90-380

SPNO/SPNC

SWITCHING RELAYS

Order

No.

Coil Voltage

@ 50/60Hz

90-340

24

MANUFACTURERS’

CATALOGS

We will be glad to send

manufacturers’ catalogs and

other available publications and

data on request.