Henry du Preez is an independent consultant with extensive

experience in ac and dc electrical machines and transform-

ers. He consults in mining and industry, locally and globally.

He offers specialised training courses in association with

‘Specialized Knowledge’ and ABB (Transformers).

Enquiries: Email

henry@hdupreez.co.za

CABLES + ACCESSORIES

• Check that oil rings are free and in place - if these are fitted

• Insulation resistance stator

• If bearings are insulated, check bearing insulation

• Motor earth connection

• Cable connections - including earthing; and if surge protection

is fitted, check connections and earthing of surge arrestors

• Temperature sensor connections and test winding and bearings

• Space heaters - if fitted

• If themotor is designed and suppliedwith pedestal bearings align-

ment and clearance are critical and must be checked. The air gap

between the rotor and stator must be checked

as bolting the motor frame down could alter

the air gap which could cause vibration and

other problems. The air gap should always

be checked in pedestal machine and large

motor where provision has been made to do

so after installation

• Run the motor uncoupled and check the cur-

rent, vibration, bearing oil rings and lubrica-

tion system

• Couple the motor and run checking current

and starting time

• Check and measure vibration

• Check and record operating current, voltage

and motor conditions (temperatures and

vibration)

• Set protection to the correct operating condi-

tions and motor specifications

These values must be checked against the re-

pairer or manufacturers test report.

Conclusion

It is important to install the motor with care and

monitor the operation conditions if the motor is

to operate for the expected service life.

References

[1] Du Preez, H. 2014. Is Partial Discharge an Is-

sue? Electricity+Control, July 2014.12.09

[2] IEC 60034-18-41. 2014. Rotating electrical

machines - Part 18-41: Partial discharge free

electrical insulation systems (Type I) used in

rotating electrical machines fed from voltage

converters - Qualification and quality control

tests.

[3] Nailen RL. Managing Motors. PE Barks Pub-

lications Inc.

DRIVES, MOTORS + WITCHGEAR

MARTHINUSEN AND COUTTS - LEADERS IN ELECTRIC MOTOR AND POWER GENERATION REPAIR, MAINTENANCE AND SPECIALISED MANUFACTURE. Large AC / DC Motors Small AC / DC Motors Traction & Flameproof Motors Transformers Power Generation ON SITE SERVICES Removal repair and re-installation On site testing and breakdown repair Root cause analysis Condition monitoring Preventative and predictive maintenance Motor management programme Reliability improvements/enhancements Efficiency improvements Performance upgrades Power savings CUSTOMISED ELECTRICAL AND MECHANICAL DESIGN Marthinusen & Coutts Your Assets. Your Needs. Your Service Partner. Tel: +27 (0)11 607 1700 www.mandc.co.za commercial@mandc.co.za