asecos Catalogue 2013/14 - page 306-307

GAP
-LINE
306
307
Model
Material/Colour/Informationn
W
x
D
x
H (mm)
Order N
o
.
APA.145.075
750 x 600 x 1450
26389
n
APA.145.090
900 x 600 x 1450
26396
n
Accessories
Dimensions
Media supplies
natural gas, water (cold), drain
25497
n
Media supplies
water (cold), drain
25120
n
Media supplies
natural gas
25121
n
Support frame für APA.145.075
melamine, sheet steel plastic laminated RAL 7035
9500
n
Support frame für APA.145.090
melamine, sheet steel plastic laminated RAL 7035
8264
n
Ventilation set 1
ventilation accessories
Ø 100 mm, 1 m Hose
27403
n
Ventilation set 2
ventilation accessories
Ø 125 mm, 7,5 m Hose
27404
n
Ventilation set 3
support fan
Ø 125 mm, 7,5 m Hose
27571
n
Hazardous material workplace (pharmaceutical exhausts)
according to DIN 12924 Part 4: 2012
• safe handling of chemicals, protection from hazardous vapours
and potentially explosive atmospheres
• easily mounted on a table top
• robust construction made of chemically resistant, antibacterial
plastic laminated sheet steel
• testing of the air equipment by recognized test institute
Standard equipment
• exhaust air monitoring
• 2 sockets
• workplace lighting
• acrylic glass sliding windows with continuously adjustable height
• exhaust air fan
Optional available:
Ventilation set 1
• 1 m flexible hose DN100
• 2 hose clamps
• 1 wall bushing
Ventilation set 2
• 7,5 m flexible hose DN125
• 2 hose clamps
• 1 wall bushing
• 1 reducing adapter DN100/125
Ventilation set 3
• 1 fan DN150
• 2 reducing adapters DN150/125
• 7,5 m flexible hose DN125
• 2 hose clamps
• 6 drilling screws 4,2 x 16
Pharmaceutical exhaust model APA.145.090
(Media supply optional)
Order No. 26396
Technical Data
Pharmaceutical exhaust model
APA.145.075
APA.145.090
Outer dimensions in mm
height
1450
1450
width
750
900
depth
600
600
Inner dimensions in mm
clear Height
930
930
width
740
890
depth
440
440
Usable working surface (mm)
width
745
895
depth
480
480
total weight (kg)
55
65
extraction air inlet (NW/mm)
100
100
recommended exhaust air flow (m
3
/h)
330
330
approx. pressure loss (Pa)
315
315
earthed sockets IP 54 (pieces)
2
2
Media supplies (optional)
Drain, natural gas, water
Drain, natural gas, water
waste water connection (Inch)
1,5
1,5
gas- / waste water connection (mm)
12
12
Electric (all models)
Power supply 230 V, 50 Hz, energy-saving lamp, on-off switch, light switch, monitoring electronics, supply air fan(s), 2 earthed sockets 230 V, 50 Hz. The unit is protected with 4A fuse.
All figures are approximate values
Views APA.145.075
Views APA.145.090
A- A ( 1 : 10 )
A
A
1460
750
500
Öffnung Front
421
151 150
141
636
Schieber offen
Entnahme Erdgas
(optional)
Entnahme Wasser, kalt
(optional)
679
Öffnungsbreite
924
Höhe innen
900
107
Dosierventil Medienversorgung
Wasser, kalt (optional)
Dosierventil Medienversorgung
Erdgas (optional)
Schalter Ein/Aus
Schutzkontaktsteckdose (IP54, 2x)
Ventilatorgehäuse
69
Anzeige
Überwachungselektronik
Uniflex-Schläuche Überwurfmutter 1/2"
Überstehende Länge ca.450
Ablauf-Anschluß für
40-Sanitärrohr
A- A ( 1 : 10 )
A
A
1460
900
500
Öffnung Front
421
151 150
141
636
Schieber offen
Entnahme Erdgas
(optional)
Entnahme Wasser, kalt
(optional)
829
Öffnungsbreite
924
Höhe innen
900
107
Dosierventil Medienversorgung
Wasser, kalt (optional)
Dosierventil Medienversorgung
Erdgas (optional)
Schalter Ein/Aus
Schutzkontaktsteckdose (IP54, 2x)
Ventilatorgehäuse
69
Anzeige
Überwachungselektronik
Ablauf-Anschluß für
40-Sanitärrohr
Uniflex-Schläuche Überwurfmutter 1/2"
Überstehende Länge ca.450
DIN
12924-4
2012
60 cm
90cm
75 cm
Ready for dispatch within
n
2 weeks
Pharmaceutical Exhaust
Pharmaceutical Exhaust
Extraction air monitoring
Sash open
Water supply, cold
(optional)
Natur l gas supply
(optional)
Opening width
Earthed sockets (IP 54, 2x)
Switch on/off
Metering va ve m dia supply
Fan h using
Opening front
Inner height
Drain con e tion o
Ø 40 sanitary pipe
Uniflex-hoses union nut 1/2½”
Ov rlappi g length approx. 450
Fa housing
Extraction air monitoring
Sash open
Water supply, cold
(optional)
Natur l gas supply
(optional)
Opening width
Earthed sockets (IP 54, 2x)
witch on/off
Metering valve m dia supply
Metering valve m dia supply
Opening front
Inner height
Drain con e tion o
Ø 40 sanitary pipe
Uniflex-hoses union n t 1/2½”
Overlappi g length approx. 450
1...,286-287,288-289,290-291,292-293,294-295,296-297,298-299,300-301,302-303,304-305 308-309,310-311,312-313,314-315,316-317,318-319,320-321,322-323,324-325,326-327,...348
Powered by FlippingBook