asecos Catalogue 2013/14 - page 308-309

GAP
-LINE
309
Ready for dispatch within
n
2 days
Suction hoods
ASE.50.6.4
ASE.50.9.4
ASE.90.9.6
ASE.90.12.6
Dimensions W x D x H (mm)
600
×
500
×
400
900
×
500
×
400
900
×
900
×
600
1200
×
900
×
600
Front access openning W x H (mm)
484
×
437
600
×
437
600
×
452
900
×
452
Order No.
16553
n
16554
n
16555
n
16556
n
Radial fans -
safe technical ventilation of hazardous material
workplaces in accordance with regulations
• impeller of PPS, housing of PP
• CE conformity
• protection class IP 55
• incl. mounting bracket with shock absorber
Radial fan
Order No. 8679
Current limiting circuit-breaker required in case the radial fans need
to be switched on / off by the hazardous material workplace
Order No. 10808 for EH.VE.8679
Order No. 22917 for EH.VE.8680
Suction hoods -
safe working with open containers or
other sources of harmful substances/vapours
• ventilation testing of the air equipment in accordance with
EN 14175-3 (5.4.4)
• the prescribed specified workplace limit values are maintained
• ideal for assembly on an existing workplace
• robust construction made of chemically resistant,
anodised aluminium profiles
• fracture-resistant acrylic glass, 5 mm
• mounting on an on-site air exhaust system
• connecting pieces (DN 160) in the ceiling for
connection to the on-site exhaust air system
• the air speed should be
0,3 m/s
Suction hood model ASE.50.6.4
Order No. 16553
Suction hood model ASE.90.9.6
Order No. 16555
Radial fans
EH.EV.8679
EH.EV.8680
EP.VE.20657
EP.VE.20658
Current limiting circuit-breaker
Dimensions W x D x H (mm)
500
×
450
×
540
640
×
480
×
630
520
×
450
×
510
650
×
500
×
640
180
×
115
×
180
180
× 115 × 180
Weight (kg)
15
25
15
25
Order No.
8679
n
8680
n
19361
n
19360
n
10808
n
22917
n
Technical Data
EH.VE.8679
EH.VE.8680
EP.VE.20657
EP.VE.20658
Connecting fitting (NW)
160
200
160
200
Motor rating (kw)
0,12
0,25
0,12
0,25
Nominal voltage (V)
3 × 230 / 400
3 × 230 / 400
3 × 400
3 × 400
Frequency (Hz)
50/60
50/60
50/60
50/60
Current input (A)
1,12 / 0,64
1,58 / 0,91
0,48
0,79
Volumetric flow (m
3
/h)
100-900
100-1800
130-800
200-1750
Pressure drop (PA)
250-100
500-180
290-100
390-200
Noise level dB (A)
48
55
45
55
Revolutions (rpm)
1450
1450
1360
1370
Fan protection class
-
-
II 3G c IIB T3 x
II 3G c IIB T3 x
Motor
-
-
EEx e II G T3
EEx e II G T3
Technical data
ASE.50.6.4
ASE.50.9.4
ASE.90.9.6
ASE.90.12.6
Extraction air connection (NW)
160
160
160
160
Recom. extraction air amount (m
3
/h) 250
300
360
540
Pressure drop (Pa)
45
64
93
208
Explosion proof version
Fans
308
Ready for dispatch within
n
4 weeks
Suction Hoods
1...,288-289,290-291,292-293,294-295,296-297,298-299,300-301,302-303,304-305,306-307 310-311,312-313,314-315,316-317,318-319,320-321,322-323,324-325,326-327,328-329,...348
Powered by FlippingBook