Ma n Office: 405-631-9701
288
Fax: 405-631-0585
L
|
HVAC
Optional Floor Stand
- The optional floor
stand allows the heater
to be installed safely on
the floor.
Optional Blower
- Increases warm air
circulation throughout
the room with the
optional blower.
FLOOR FURNACE & VENT-FREE ROOM HEATERS
The Empire Blue Flame
TM
Locke#
Model#
Description
Gas
L3004
BF-10-1-NAT 10,000 BTU INPUT Natural
L3005
BF-10-1-LP 10,000 BTU INPUT
LPG
L0665
BF-20-1-NAT 20,000 BTU INPUT Natural
L0657
BF-20-1-LP 20,000 BTU INPUT
LPG
L3119
SRS-18 Stand for L3004, L3005,
L0665 & L0657
(Optional)
L3115
SRB-18T Blower for L3004, L3005,
L0665 & L0657
(Optional)
L0978
BF-30-1-NAT 30,000 BTU INPUT Natural
L0979
BF-30-1-LP 30,000 BTU INPUT
LPG
L3120
SRS-30 Stand for L0978 & L0979 (Optional)
L3117
SRB-30T Blower for L0978 & L0979 (Optional)
FLOOR FURNACE & VENT-FREE ROOM HEATERS
MODEL
BF-10-1
BF-20-1
BF-30-1
Color: Cabinet and Front Panel
Beige & Tan
Beige & Tan
Beige & Tan
BTU Input
10,000
20,000
30,000
OVERALL DIMENSIONS:
Width
18"
18"
24
8
"
Cabinet Depth
6½"
6½"
6½"
Height
22"
22"
22"
Shipping Weight, Lbs. (One Carton)
27
27
35
TEMPERATURE CONTROL Type
Hydraulic
Thermostat
Modulating Hydraulic
Thermostat
Modulating Hydraulic
Thermostat
Number of Heat Settings
N/A
N/A
N/A
ACCESSORIES (State on Order)
Blower Package
SRB-18T (Auto)
SRB-18T (Auto)
SRB-30T (Auto)
One-Piece Floor Installation Stand
SRS-18
SRS-18
SRS-30
MINIMUM CLEARANCES TO COMBUSTIBLES FROM:
Top
36"
36"
36"
Each Side
5"
5"
5"
Bottom to Floor (Wall Mounted)
2"
2"
2"
Bottom to Floor (Floor Mounted)
2"
2"
2"
GAS INLET
Type of Gas (State on Order)
Natural or LP
Natural or LP
Natural or LP
Iron Pipe Size (N.P.T.)
3/8"
3/8"
3/8"
IGNITION SYSTEM -
Standing pilot/piezo on all models.
SAFETY CONTROL -
Pilot equipped with automatic shut-off and oxygen depletion sensor on all models.
WARRANTY -
All parts carry a 5 year limited warranty.
NATURAL GAS FLOOR FURNACES
AUTOMATIC IGNITION!
NO MATCHES NEEDED!
""PUSH-BUTTON"" ON-OFF
LIGHTER!
Locke#
Model
Input
BTU
Floor Opening,
Length & Width Height
Temperature
Control Millivolt
Wall Therm.
L0994
3588-2 32,500 32
c
" x 20
c
" 23½"
Yes
L0969
5088-2 45,000 34
c
" x 22
c
" 25¾"
Yes
SAFETY CONTROL - Pilot & main burners include Automatic
Shutoff, Temperature Limit Controls, Flood Pan & Debris Pan.
WARRANTY - Combustion chamber carries a 10 year limited