Table of Contents Table of Contents
Previous Page  459 / 1070 Next Page
Information
Show Menu
Previous Page 459 / 1070 Next Page
Page Background

Credit: 405-631-9756

459

www.lockesuppl .com

L

|

HVAC

GAS VALVES

720-070

720-052

720-007

24 VOLT HOT SURFACE MODEL

Specifications:

Electrical Rating:

24 VAC, 5 amps

Pressure Regulator:

Natural Gas:

Factory set @ 3.5" W.C.

LP Gas:

Factory set @ 11.0" W.C.

Pilot outlet:

¼" tubing

Ambient temperature:

-40° to 175° F

Maximum inlet pressure: 7" W.C. - natural gas / 14" W.C. - LP Gas

24 VOLT HOT SURFACE IGNITION

Reducer Bushings Included:

Locke#

Vendor# Factory

Model

Inlet Size Outlet Size Pressure Regulator

Setting

Capacity ¾" x ½"

L0396

720-051 7200-DER 1/2"

3/4"

UNI-KIT

150,000

1

24 VOLT STEP-OPENING/CONVERTIBLE**

FOR MOBILE HOMES

Specifications:

Electrical Rating:

24 VAC, 5 amps

Pressure Regulator:

Factory set @3.5" W.C. (Natural Gas),@11.0" W.C.(LP Gas)

Pilot outlet:

¼" tubing

Ambient temperature:

-40° to 175° F

Maximum inlet pressure: 7" W.C. - natural gas / 14" W.C. - LP Gas

** Convertible regulator for mobile home use. Select 3.5" W.C. natural gas or 11.0" W.C. L.P. Gas.

24 VOLT STEP-OPENING CONVERTIBLE

Locke#

Uni-Line

Number

Factory

Model

Inlet Size

(FPT)

Outlet

Size (FPT) Capacity Reducer Bushings Included (NPT)

¾"x½" ½"x

a

" ¾"x

a

" Replaces

L0392

720-007 7200ERC 1/2"

1/2"

150,000

120-402 AND 120-407

L0394

720-474 7200ERCS 1/2"

1/2"

150,000

120-473 AND 120-474

720 SERIES PILOT IGNITION GAS VALVES

Specifications:

Electrical Rating:

24 VAC, 50/60 Hz .45 amps

Power Consumption:

5 watts

NEC:

Class 2

Terminal Connections:

¼" quick-connect

Pilot outlet:

¼" tubing

Ambient temperature:

-40° to 175° F Max.

Maximum inlet pressure:

14" W.C. (1/2 PSI)

Pressure regulator setting:

UNI-KIT

Locke#

Vendor# Factory Model

Description

L0558

720-070 72001PERS7C ½" Inlet x ¾" Outlet Size. Includes (1) ¾" to ½" reducer bushing.

Pressure regulator setting is UNI-KIT. 150,000 BTU

REDUNDANT OEM VALVE

This gas valve is designed for direct spark ignition, hot surface ignition & proven pilot system applications. It is

equipped with redundant (pilot) & main solenoid valves that control gas flow to the main burners &/ or pilot, a

field-adjustable outlet pressure regulator, & a two-position on/off switch for electrical shut-off.

Specifications:

Natural Gas OR LP Gas; 24 VAC; 50/60 Hz

Ambient temperature: -40° F to 175° F

Pressure Rating: 14" W.C. (½ PSI) max.

Locke#

Model# Pipe Sizes Available (inches)

Capacity at 1" Pressure Drop across valve

AGA Std. Nat. Gas (1,000 BTU/cu. ft.) LP Gas (2,500 BTU/cu. ft.)

L0795

36E24-214 ½" x

a

" NPT straight through

100,000

162,000