463

www.lockesuppl .com

L

|

HVAC

TIMED CONTROLS AND SEQUENCERS

8140 SERIES 40 AMP,

TIME INITIATED, TEMP OR

PRESSURE TERMINATED

Frequency of defrost is one to six cycles

per day. A minimum of four hours between

successive defrost cycles.

Adjustable back-up defrost termination from

four-110 minutes in two minute increments.

Control works with an external temperature

or pressure sensor.

Switch ratings per pole: 40 amp, 2 hp, 690

VA pilot duty, 120-240 volts AC. "

Heavy steel enclosure. Gray finish.

Knockouts at bottom, back and sides. Hasp

and staple for padlock. Available on bracket

for sub-panel mounting.

Operating voltage: 120 or 208-240 volt, 60

Hz (50 Hz -see chart below).

Heavy duty, synchronous industrial type

motor.

First transfer after refrigeration

cycle: (A633-20) 2-4 remains closed

(compressor). 1-3 opens (fan).

Second transfer: (3-6 minutes after the first)

2-4 opens (compressor). 1-3 remains open

(fan).

NORMAL POSITION OF CONTACTS

DURING REFRIGERATION CYCLE

CONTACT 1-3 CONTACT 2-4

Open

Closed

Open

Closed

Locke#

UNI-LINE

50 HZ VOLTS/

60 HZ

L0748 8145-00

120

L0749 8145-20

208/240

COMMERCIAL DEFROST

CONTROLS

8040 SERIES

TIME INITIATED,

TIME TERMINATED

Used in conjunction with a temperature or

pressure control on hot gas or compressor

systems and electric heat applications. Up to 6

defrost cycles per day with defrost times from

4 to 110 minutes in 2 minute increments. Gray

NEMA type 1 indoor enclosure. Includes 4 dial

pins. 60 Hz. 40 Amps. 2 HP. 690 VA. 120 or

208-240 Volts. SPOT Contacts.

Locke#

L0737

8045-00 120v

L0738

8045-20 208-240v

THERMAL CUTOUTS

L1100 & L1101

L1106 & L1107

Locke#

Vendor# Descrip. Packaged

L1100

STC-4300 300°F

5

L1101

STC-4333 333°F

5

L1106

STC-5300 306°F

2

L1107

STC-5333 336°F

2

ELECTRIC HEAT

SEQUENCER

Replaces most fan/heat sequencing

functions.

L0791

• Ambient rated -40.

• Multi-poise mounting.

• Double quick-connected terminals for

combination loads.

• Terminal markings equivalent to competition

& allow1 wiring method for various sources

of sequencers.

• 4 Timings

• 5 Switches

Locke#

L0791

24A3414 Electric Heat

Sequencer

ELECTRIC HEAT

SEQUENCERS

L0311

& L0312

L0324

Locke#

Model# Number of

Circuits

T.O.D.

Number Seconds

L0324

TDR20 1 Main &

1 AUX 15SH2 ON 1-20

OFF 40-110

L0311

TDR30 3 Mains 15SH21 ON 1-110

OFF 1-110

L0312

GS106 4 Mains 15SH22 ON 1-110

OFF 1-110

YO

WE A

PP

R

E

C

I

A

T

E

UR

B

U

S

I

N

E

S

S

!