Background Image
Previous Page  49 / 116 Next Page
Basic version Information
Show Menu
Previous Page 49 / 116 Next Page
Page Background

47

www.read-wca.com

Wire & Cable ASIA – September/October 2013

With the Preheater 6000 TC (TC -

Temperature Control), Sikora offers a

solution for a precise conductor

preheating, the basis for high-quality

cable production.

The Preheater 6000 TC is positioned

before the extruder and preheats the

wire by means of inductive heating up to

200°C. A controlling module controls the

power of the Preheater 6000 TC

depending on the conductor material,

the conductor dimension, the line speed

and the desired temperature.

A non-contact infrared camera takes the

temperature inside the Preheater.

With the approach of the direct

integration of a wire temperature

measurement in the Preheater and the

feedback to its power control, it is

assured that the wire temperature is

always at its desired level. The Preheater

is available for a product diameter of

0.32 to 2.8mm (0.08 to 6mm²) and

applicable for new lines as well as the

retrofitting on existing lines. The system

comes with all common interfaces such

Ethernet, Profibus and Profinet as well

as analogue ports.

Initially developed for Sikora’s Preheater,

the Wire-Temp 6000 is also now

available as a standalone version and for

retrofitting to existing preheaters. The

Wire-Temp 6000 determines the

conductor temperature independently

from the cross-section, the material, the

line speed and the surface structure of

the conductor.

A big advantage over conventional

systems is that the temperature

measurement is made by means of a

non-contact thermal image sensor in an

infrared camera, which detects the

conductor and provides accurate

measurements with no need for

calibration. The Wire-Temp 6000 is

available for product sizes from 0.1 to

10mm and from 0.15 to 100mm.

Various communication interfaces are

available for the transmission of the

measuring values to a Sikora processor

system, the line control or a laptop. The

universal

interface

module

for

connections to RS485, RS232, Profibus

DP or industrial field buses such as

CANopen,

Ethernet/IP,

DeviceNet,

Profinet IO fulfils the demand. The

interface module and all connection

plugs are fully sealed for protection

against water, dirt and mechanical

damage.

Sikora AG – Germany

Website

:

www.sikora.net

Preheating with temperature control

Preheater 6000 TC with integrated

Wire-Temp 6000

Category 8 for data

Datwyler has developed ‘CU 8203 4P’,

a compact S/FTP AWG23 cable which

complies fully with the anticipated

requirements of the new Category 8.2

as specified in the ISO/IEC draft.

The new international standards for

Category 8 copper cable and

balanced cabling systems for 40

Gbit/s are currently being developed

as Draft Standards IEC 46C/976/NP

and ISO/IEC TR 11801-99-1.

Unlike the proposed standards for

symmetrical Category 8 data cables

discussed a few years ago, the sole

use foreseen by today‘s international

standardisation bodies is in data

centres with a maximum limiting

frequency of 2 GHz.

Standard ISO/IEC TR 11801-99-1

defines a point-to-point connection

between active devices at a maximum

distance of 30 metres, comprising 26

metres of installation cable and 2

metres of patch cable on either side.

Such a connection can replace

expensive fibre optic and twinax

cabling in data centres.

Datwyler Cables GmbH – Germany

Website

:

www.cabling.datwyler.com