Swaged or MGO thermocouples have a metal sheath and compacted

Magnesium Oxide powder for insulation. Since they have ceramic

insulation, swaged thermocouples can go to a much higher temperature

than Miniature and Probe types.

Swaged thermocouples are very

flexible and can safely handle a bend around a surface two times

the diameter of the sheath.

!

Note:

If you would like to order a Type E, J, N, or Type T assembly,

just substitute the K with a E, J, N, or T in the part numbers listed on

this page. Double element assemblies are also available.

Add a ”

D

” to the part number.

Example: 18K4DS9-G-K1-*

Swaged thermocouples are also available in Types B, C, R, and S.

Sheath materials other than the common ones listed at the bottom of

this page can be ordered. Some of these include: Molybdenum,

Tantalum, or Hastelloy. Phone one of our sales engineers for details.

We understand how important the quality of our thermocouples is to

our customers. This is why our thermocouples are made with high

purity Magnesium Oxide insulation and conductors which are within

special limits of error.

Application

Wire

Gauge

Outside Diameter

Inches mm

Type K

1

Swaged or MGO, Male Plug

Swaged thermocouple with a standard size plug. The plug is constructed with

solid

pins. We do not sacrifice quality by selling plugs with hollow pins.

A 1/8” NPT 316 stainless steel compression fitting (

CF

) can also be specified

by adding “

CF

” to the end of the part number. A grounded junction is standard

for rapid temperature response.

8

11

14

16

18

20

24

30

3/4

1/2

3/8

5/16

1/4

3/16

1/8

1/16

19.1

12.7

9.5

7.9

6.4

4.8

3.2

1.6

8K4S9-G-K7-*

11K4S9-G-K4-*

14K4S9-G-K1-*

16K4S9-G-K1-*

18K4S9-G-K1-*

20K4S9-G-K1-*

24K4S9-G-K1-*

30K4S9-G-K1-*

2

Swaged or MGO, Female Jack

Swaged thermocouples typically have a male plug installed on the sheath, but

are available with standard size female jack option. A 1/8” NPT 316 stainless

steel compression fitting (

CF

) can also be specified by adding “

CF

” to the end

of the part number. A grounded junction is standard for rapid temperature

response.

8

11

14

16

18

20

24

30

3/4

1/2

3/8

5/16

1/4

3/16

1/8

1/16

19.1

12.7

9.5

7.9

6.4

4.8

3.2

1.6

8K4S9-G-K8-*

11K4S9-G-K5-*

14K4S9-G-K5-*

16K4S9-G-K2-*

18K4S9-G-K2-*

20K4S9-G-K2-*

24K4S9-G-K2-*

30K4S9-G-K2-*

3

Swaged or MGO, Male Plug & Female Jack

Swaged thermocouples with a male plug and mating female jack. The plug is

constructed with

solid

pins. We do not sacrifice quality by selling plugs with

hollow pins. A female jack is also provided for attaching your lead wire. A 1/8”

NPT 316 stainless steel compression fitting (

CF

) can also be specified by

adding “

CF

” to the end of the part number. A grounded junction is standard for

rapid temperature response.

8

11

14

16

18

20

24

30

3/4

1/2

3/8

5/16

1/4

3/16

1/8

1/16

19.1

12.7

9.5

7.9

6.4

4.8

3.2

1.6

8K4S9-G-K9-*

11K4S9-G-K6-*

14K4S9-G-K6-*

16K4S9-G-K3-*

18K4S9-G-K3-*

20K4S9-G-K3-*

24K4S9-G-K3-*

30K4S9-G-K3-*

4

Swaged or MGO, Open Terminal (OTH)

Swaged open terminal block assemblies can be exposed for easy access.

They are useful in situations where a low profile is needed. The terminal block

is ceramic for maximum heat resistance. A 1/8” NPT 316 stainless steel

compression fitting (

CF

) can also be specified by adding “

CF

” to the end of the

part number. A grounded junction is standard

18

20

24

1/4

3/16

1/8

6.4

4.8

3.2

18K4S9-G-OTH4-*

20K4S9-G-OTH3-*

24K4S9-G-OTH2-*

Temperature Limits

Note: Limits are based on Type K thermocouples.

O.D.

Inches

Approx.

Gauge

# 8 or # 16

Alloy

# 9 or # 20

Alloy

# 23

Alloy

3/4

8

870°C 1600°F 1090°C 2000°F

-

-

1/2

11

870°C 1600°F 1090°C 2000°F

-

-

3/8

14

870°C 1600°F 1090°C 2000°F

-

-

5/16

16

870°C 1600°F 1090°C 2000°F

-

-

1/4

18

870°C 1600°F 980°C 1800°F 1260°C 2200°F

3/16

20

870°C 1600°F 870°C 1600°F 1260°C 2200°F

1/8

24

870°C 1600°F 870°C 1600°F 1260°C 2200°F

1/16

30

800°C 1470°F 800°C 1470°F 1260°C 2200°F

* Add required thermocouple length. Multiples of 6” (152.4 mm) starting at 12” are in stock. Note: * = Probe length in figures shown.

#9 Alloy (600) is standard, #7 (446SS), #8 (304SS), #16 (316SS), #23 (2200 cable) can be requested. Just replace the “9” in the part number.

Thermocouples - Swaged or MGO Assemblies

Page 42

Phone: 617.527.4385 Fax: 617.964.3746 Email: