Previous Page  44 / 204 Next Page
Information
Show Menu
Previous Page 44 / 204 Next Page
Page Background

Swaged or MGO thermocouples have a metal sheath and compacted

Magnesium Oxide powder for insulation. Since they have ceramic

insulation, swaged thermocouples can go to a much higher temperature

than Miniature and Probe types.

Swaged thermocouples are very

flexible and can safely handle a bend around a surface two times

the diameter of the sheath.

!

Note:

If you would like to order a Type E, J, N, or Type T assembly,

just substitute the K with a E, J, N, or T in the part numbers listed on

this page. Double element assemblies are also available.

Add a ”

D

” to the part number.

Example: 18K4DS9-G-K1-*

Swaged thermocouples are also available in Types B, C, R, and S.

Sheath materials other than the common ones listed at the bottom of

this page can be ordered. Some of these include: Molybdenum,

Tantalum, or Hastelloy. Phone one of our sales engineers for details.

We understand how important the quality of our thermocouples is to

our customers. This is why our thermocouples are made with high

purity Magnesium Oxide insulation and conductors which are within

special limits of error. A grounded junction is standard for quick response.

Application

Wire

Gauge

Outside Diameter

Inches mm

Type K

1

Hex Fitting (HX)

Swaged thermocouple with a hex fitting (

HX

) are used where a 316 stainless

steel 1/2” x 1/2” NPT fitting is desirable for mounting to the process and to the

connection head. The hex fittings are welded to the sheath for strength and

proper seating. Other size Hex Fittings are also available - consult factory.

2” bare leads are standard.

8

11

14

16

18

20

24

3/4

1/2

3/8

5/16

1/4

3/16

1/8

19.1

12.7

9.5

7.9

6.4

4.8

3.2

8K4S9-G-HX-*

11K4S9-G-HX-*

14K4S9-G-HX-*

16K4S9-G-HX-*

18K4S9-G-HX-*

20K4S9-G-HX-*

24K4S9-G-HX-*

2

Hex Fitting (HX) and Standard Head (Aluminum) (SH)

Swaged thermocouple with a hex fitting (

HX

) are used where a 316 stainless

steel 1/2” x 1/2” NPT fitting is desirable for mounting to the process and to the

connection head. The hex fittings are welded to the sheath for strength and

proper seating. These assemblies come with our (

SH

) Standard Heads.

8

11

14

16

18

20

24

3/4

1/2

3/8

5/16

1/4

3/16

1/8

19.1

12.7

9.5

7.9

6.4

4.8

3.2

8K4S9-G-HX-*-SH

11K4S9-G-HX-*-SH

14K4S9-G-HX-*-SH

16K4S9-G-HX-*-SH

18K4S9-G-HX-*-SH

20K4S9-G-HX-*-SH

24K4S9-G-HX-*-SH

3

Two Compression Fittings (CF) and

Standard Head (Aluminum) (SH)

A Compression Fitting (

CF

) is used to mount the Head instead of a hex fitting.

These assemblies come with a (

SH

) Standard Head. A second 1/8” NPT 316

stainless steel compression fitting (

CF

) is added by the “

CF

” at the end of the

part number to allow for adjusting the depth of insertion.

8

11

14

16

18

20

24

3/4

1/2

3/8

5/16

1/4

3/16

1/8

19.1

12.7

9.5

7.9

6.4

4.8

3.2

8K4S9-G-*-SH-CF

11K4S9-G-*-SH-CF

14K4S9-G-*-SH-CF

16K4S9-G-*-SH-CF

18K4S9-G-*-SH-CF

20K4S9-G-*-SH-CF

24K4S9-G-*-SH-CF

4

Transition Fitting (TF)

These

assemblies have extension wire attached to the thermocouple. This is

beneficial when the instrument is located some distance from the area where

the temperature is being measured. A relief Spring (

SR

) is installed to give

protection to the potted junction. 3” of split leads are standard. A 316 stainless

steel compression fitting (

CF

) allows for adjusting the depth of insertion.

18

20

24

1/4

3/16

1/8

6.4

4.8

3.2

18K4S9-G-Y-TR-X

20K4S9-G-Y-TR-X

24K4S9-G-Y-TR-X

5

Transition Fittings (TR) and Armored Cable (AC)

These assemblies are the same as the ones above but with a some length (

Z

)

of Armored Cable on the extension wire.

18

20

24

1/4

3/16

1/8

6.4

4.8

3.2

18K4S9-G-Y-TR-X-Z

20K4S9-G-Y-TR-X-Z

24K4S9-G-Y-TR-X-Z

Temperature Limits

Note: Limits are based on Type K thermocouples.

* Add required thermocouple length. Multiples of 6” (152.4 mm) starting at 12” are in stock. Note: * = Probe length in figures shown.

#9 Alloy (600) is standard, but #7 (446SS), #8 (304SS), #16 (316SS), #23 (2200 cable) can be requested. Just replace the “9” in the part number.

O.D.

Inches

Approx.

Gauge

# 8 or # 16

Alloy

# 9 or # 20

Alloy

# 23

Alloy

3/4

8

870°C 1600°F 1090°C 2000°F

-

-

1/2

11

870°C 1600°F 1090°C 2000°F

-

-

3/8

14

870°C 1600°F 1090°C 2000°F

-

-

5/16

16

870°C 1600°F 1090°C 2000°F

-

-

1/4

18

870°C 1600°F 980°C 1800°F 1260°C 2200°F

3/16

20

870°C 1600°F 870°C 1600°F 1260°C 2200°F

1/8

24

870°C 1600°F 870°C 1600°F 1260°C 2200°F

1/16

30

800°C 1470°F 800°C 1470°F 1260°C 2200°F

Thermocouples - Swaged or MGO Assemblies

Page 44

Phone: 617.527.4385 Fax: 617.964.3746 Email: