Stakeholder Panel Meeting Book - September 6, 2014 - page 61

AOAC SMPR 2014.XXX; Version 2; March 19, 2014
1
2
Method Name: Determination of Amino Acids in Infant and
3
Adult/Pediatric Nutritional Formula
4
5
Approved by:
Stakeholder Panel for
Infant Formula and Adult Nutritionals
6
Final version date
:
7
Effective date:
8
9
Intended Use:
Reference method for dispute resolution.
10
11
1.
Applicability:
12
Determination of free and/or total proteinogenic L-
α
-amino acids and taurine (as
13
shown in Table 1) in all forms of infant, adult, and/or pediatric formulas (powders,
14
ready-to-feed liquids, and liquid concentrates).
15
16
2.
Analytical Technique:
17
Any analytical technique that meets the following method performance
18
requirements is acceptable.
19
20
3.
Definitions:
21
Accuracy
1
22
The closeness of agreement between the average of an infinite number of replicate
23
measured quantity values and a reference quantity value.
24
25
Adult/Pediatric Formula
26
Nutritionally complete, specially formulated food, consumed in liquid form, which may
27
constitute the sole source of nourishment
2
, made from any combination of milk, soy,
28
rice, whey, hydrolyzed protein, starch, and amino acids, with and without intact
29
protein.
30
31
Infant formula
32
Breast-milk substitute specially manufactured to satisfy, by itself, the nutritional
33
requirements of infants during the first months of life up to the introduction of
34
appropriate complementary feeding
3
,
made from any combination of milk, soy, rice,
35
whey, hydrolyzed protein, starch, and amino acids, with and without intact protein.
36
37
Limit of Detection (LOD)
38
The minimum concentration or mass of analyte that can be detected in a given matrix
39
with no greater than 5% false positive risk and 5% false negative risk.
40
41
Limit of Quantitation (LOQ)
42
The minimum concentration or mass of analyte in a given matrix that can be reported
43
as a quantitative result
44
45
Repeatability
46
Variation arising when all efforts are made to keep conditions constant by using
47
the same instrument and operator, and repeating during a short time period.
48
Expressed as the repeatability standard deviation (SD
r
); or % repeatability
49
relative standard deviation (%RSD
r
).
50
51
52
1
Corresponds to the VIM definition for “trueness”.
2
AOAC Stakeholders Panel for Infant Formula and Adult Nutritionals (SPIFAN); 2010.
3
Codex Standard 72
1981.
1...,51,52,53,54,55,56,57,58,59,60 62,63,64,65,66,67,68,69,70,71,...160