TAR NC Implementation Document – Second Edition September 2017

Equalisation

At first, the distances between each entry and exit point of the system were deter-

mined. Those distances and the given capacity are the inputs to apply the RPM if

such RPM employs distance as a cost driver. Illustrative tariffs resulting from an

RPM could be:

The ex-post equalisation consists of calculating tariffs e. g. by using a capacity-

weighted average approach per following formula:

Where:

T

is the tariff of the equalised points

T

n

is the tariff of a point

C

n

is the capacity of a point

The calculated tariffs would be applied to any consumption point.

C1

4

C2

2

C3

5

Table 22:

Illustrative tariffs

Exit tariffs

C1

4

15

C2

2

10

C3

5

5

VCP

3,5

Table 23:

Tariff for the cluster

Exit tariffs

Capacity

Exit