11.4 The receiver drier

Roles:

1. To retain moisture and contaminants from the

system (during the receiver drier’s life time)

2. To finalise and secure the condensation of the fluid

3. To compensate for the variations of fluid volume

4. To ensure oil return to the compressor

The receiver drier protects the components of the

system; it is located on the high pressure

side of the circuit between the condenser outlet and

the expansion valve inlet.

Evaporator

Condenser

Expansion valve

Compressor

Receiver drier

Liquid

refrigerant

Oil

Liquid

refrigerant

Oil

Gaseous

refrigerant

Contaminants

A/C system

Recommendations for replacement:

The receiver drier must be replaced every

3 years.

Regularly replacing the filter prevents

serious failures and the costly replacement

of the other components in the air conditio-

ning system.

The receiver drier must be replaced whene-

ver the circuit is opened.

49