Option 3

Cartridge drier

Example of an application in the Valeo Air Condi-

tioning catalogue. This example shows that, when

the condenser 818004 is replaced, the receiver drier

509593

is

supplied with the condenser. It is mounted

on the condenser in production. This option is shown

in the Information column (I), which contains the

pictogram of the drier cartridge.

What you need to know to

become N°1. Recommendations

on the receiver drier.

The receiver drier must be replaced whe-

never the air conditioning loop is opened.

For example, after an accident in which

the condenser was damaged, the receiver

drier must be replaced, or the desiccator

will no longer retain the humidity in the

circuit. It will become saturated with hu-

midity.

Due to its very role, the receiver drier is

hygroscopic. Therefore it is essential to

obey the basic rules when replacing it on

a vehicle or the new receiver drier may be

damaged.

Receiver driers are fitted with compulsory

plugs that must be removed as late as pos-

sible, i.e. just before they are installed.

Warning! If the receiver drier is not replaced,

the operation of the loop will deteriorate

and the risk of a breakdown will occur (bloc-

ked expansion valve, impurities in the cir-

cuit, etc.).

In any case, the receiver drier must be ins-

talled in the loop at the very last moment,

just before the vacuum procedure.

The IRD ‘Integrated Receiver Drier’.

Both option 2 and option 3 integrate the

receiver drier in the condenser refrigerant path.

The IRD is not just about integration: it allows

reaching a much higher level of condensation

in the condenser in the long run despite

refrigerant level fluctuations.

51