10X in the system sampled at 1024 Hz:
a. Wonder Gecko, LESENSE @ 1 Hz:
1.49 µA
b. Wonder Gecko, LESENSE @ 16 Hz:
1.57 µA
c. Wonder Gecko, LESENSE @ 128 Hz:
2.06 µA
d. Wonder Gecko, LESENSE @ 1024
Hz: 5.92 µA
LESENSE can also simplify software
development by treatingmeasurements
as its own autonomous system, freeing
up the ADC for other tasks.
to be continued in our next
magazine...
Figure 4 - Wonder Gecko, Wonder Gecko, LESENSE, sampling @ 1 Hz.
New-Tech Magazine Europe l 59