d

) 

Standard Method Performance Requirements

(AOAC

SMPR® 2012.007; 1) for repeatability, reproducibility, and

recovery for the method are shown in the Table

2015.01J

.

See

AppendixA (available on the

J. AOAC Int

. website as supplemental

material,

http://aoac.publisher.ingentaconnect.com/content/aoac/

jaoac) for detailed method performance information supporting

acceptance of the method.

(

e

) 

See

AppendixAfor detailedmethod performance information

supporting acceptance of the method. Method validation samples

were prepared and analyzed for all applicable matrices. In general,

all SMPR criteria were met for As, Cd, Hg, and Pb in the matrices

apple juice, infant formula, cocoa powder, and rice flour.

References: (1) AOAC SMPR 2012.007

J. AOAC Int . 96 , 704(2013)

DOI: 10.5740/jaoac.int.2012.007

J. AOAC Int . 98 , 1113(2015)

DOI: 10.5740/jaoac.int.2015.01

Posted: September 9, 2015

Table 2015.01J. AOAC SMPR 2012.007 (ref. 1)

Concn range, μg/kg Repeatability, % Reproducibility, % Recovery, %

LOQ–100

15

32

60–115

100–1000

11

16

80–115

>1000

7.3

8

80–115

Candidates for 2016 Method of the Year

11