Table of Contents Table of Contents
Previous Page  112 / 601 Next Page
Information
Show Menu
Previous Page 112 / 601 Next Page
Page Background

Article 2: Administration

Section 2.5. Application-Specific Review Procedures

2.5.25. Wireless Telecommunication Facilities

June 23, 2017

Morrisville, NC

Page 2-86

Unified Development Ordinance

Existing Telecommunication Facilities

a.

Existing Antenna Modification, Replacement or Upgrade

For any existing antenna modification, replacement or upgrade, the applicant must, prior to

making such modifications, submit the following:

(1)

A description of the proposed revisions to the antenna, including the element design, type

and number, as well as changes in the number and/or size of any feed lines, from the

base of the equipment cabinet to such antenna elements.

(2)

A signed statement from an RF Engineer, together with their qualifications, shall be

included representing the tower’s owner or owner’s agent that the radio frequency

emissions comply with FCC standards for such emissions. The statement shall also certify

that both individually and cumulatively, and with any other facilities located on or

immediately adjacent to the proposed facility, the revised antenna complies with FCC

standards.

(3)

A sealed structural analysis of the existing structure prepared by a registered Professional

Engineer licensed by the State of North Carolina indicating that the existing tower as well

as all existing and proposed appurtenances meets current NC Building Code

requirements, including, but not limited to, wind loading and ANSI EIA/TIA 222 standards,

for the tower.

b.

Telecommunication Tower Replacement or Mitigation (not involving collocation)

(1)

General

(A)

Tower replacement or mitigation (not involving collocation) shall accomplish a

minimum of one of the following:

(i)

Reduce the number of towers.

(ii)

Reduce the number of nonconforming towers.

(iii)

Replace an existing tower with a new tower to improve network functionality

resulting in compliance with this ordinance.

(B)

No tower shall be mitigated more than one time.

(2)

Telecommunication Tower Design and Construction

Towers shall be engineered and constructed as follows:

(A)

All towers up to 120 feet in height shall accommodate no less than three antenna

arrays.

(B)

All towers between 120 feet one-inch and 140 feet shall accommodate no less than

four antenna arrays.

(C)

All towers between 140 feet one-inch and 199 feet shall be engineered and

constructed to accommodate at least five antenna arrays.

(3)

Height

The height of a tower approved for replacement or mitigation shall not exceed one-

hundred percent of the height of the tower being replaced or mitigated. For example,

an existing 170 foot tower could be rebuilt at 170 feet.

(4)

Breakpoint Technology

New replacement towers or towers used for mitigation shall be designed using breakpoint

technology. Certification by a registered Professional Engineer licensed by the State of